IBM Support

PH28515: INCORRECT SSRANGE CHECKING ON REFERENCE MODIFICATION OF UNBOUNDED DATA ITEMS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Incorrect SSRANGE checking on reference modification of
    UNBOUNDED data items
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 who compile   *
    *                 with SSRANGE compiler option and have a      *
    *                 source program with CALL sub USING with a    *
    *                 USING parameter that contains an UNBOUNDED   *
    *                 table that is reference modified.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: The program gets an incorrect run time  *
    *                      error for a reference modification      *
    *                      start value that is beyond the end of   *
    *                      the table, even though the reference    *
    *                      modification start value is actually    *
    *                      perfectly OK.                           *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The compiler is not supposed to be checking reference
    modification of a variable-length table on a CALL statement,
    because it would force all parms to be initialized before the
    CALL.   Parameters could be input only (set by the called
    program).  The incorrect message was because this checking was
    NOT disabled and there was no length of the unbounded table to
    check against without being able to call the calc routines that
    figure out the length and require the ODO object be set before
    the CALL.
    

Problem conclusion

  • The compiler was changed to not do SSRANGE checking for
    UNBOUNDED tables on CALL sub USING phrases.  This is consistent
    with other parameters that are variable length.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH28515

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-08-14

  • Closed date

    2020-10-07

  • Last modified date

    2020-11-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH31467

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYMSGXT IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI71972

       UP20/10/10 P F010

  • R621 PSY UI71973

       UP20/10/10 P F010

  • R622 PSY UI71974

       UP20/10/10 P F010

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: