Error description
The messages IGZ0304W through IGZ0314W introduced by APAR PI72127 were intended to improve SSRANGE messaging by showing the program name incurring the SSRANGE condition. While this works in the batch environment, in the CICS environment the program name is blank.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.1 compiling and * * running programs in a CICS environment * * where the program is compiled with the * * SSRANGE option in effect. * **************************************************************** * PROBLEM DESCRIPTION: Bad runtime message output. * * * * SSRANGE-related runtime messages may * * contain an invalid value for the name * * of the affected program. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** When generating code for SSRANGE runtime messages, the compiler would sometimes avoid generating code to explicitly set up the message insert for the name of the affected program and would instead rely on the runtime to fill in the program name value, but this method is not always reliable in a CICS environment.
Problem conclusion
The compiler was updated to ensure that the program name message insert for SSRANGE-related messages is always explicitly specified.
Temporary fix
Comments
APAR Information
APAR number
PH26110
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-04
Closed date
2020-06-16
Last modified date
2020-07-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCCBE IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R610 PSY UI70077
UP20/06/23 P F006
R611 PSY UI70078
UP20/06/23 P F006
R612 PSY UI70079
UP20/06/23 P F006
R61H PSY UI70080
UP20/06/23 P F006
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023