IBM Support

PH25892: COMPILER FREES DCB STORAGE OF OPEN SYSIN AND SYSPRINT WHEN SYSMDECK DD MISSING

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Compiler frees DCB storage of open SYSIN and SYSPRINT when
    SYSMDECK DD missing leading to SC03 abend
    

Local fix

  • Ignore SC03 abend and look for IGYSI5013-U  An error occurred
    while attempting to open file "SYSMDECK".  Add SYSMDECK DD to
    avoid abend.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 who invoke    *
    *                 the compiler using JCL that is missing one   *
    *                 of the required data definition (DD) names   *
    *                 for either SYSIN, SYSPRINT or SYSMDECK.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Improper compiler termination after an  *
    *                      unrecoverable error situation.          *
    *                                                              *
    *                      An expected error message such as:      *
    *                                                              *
    *                      +IGYSI5013-U An error occurred while    *
    *                      attempting to open                      *
    *                      + file "SYSMDECK".                      *
    *                                                              *
    *                      is issued but is unexpectedly followed  *
    *                      by a SC03 ABEND and possibly also a     *
    *                      S0C4 in I/O-SRB processing.             *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The ABENDs occurred in the compiler abnormal termination
    processing code because the storage for open DCBs associated
    with either the SYSIN, SYSPRINT, or SYSMDECK data sets was
    freed, but the files were left in an OPEN state after compiler
    termination. When the system went through address space
    termination and cleanup, it tried to close these open data sets
    by accessing the DCBs for which the storage was already freed
    by the compiler.
    

Problem conclusion

  • The abnormal termination code in the compiler has
    been updated so that it closes any open data sets before it
    frees the storage associated with the DCBs for these open data
    sets.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH25892

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-05-28

  • Closed date

    2020-06-16

  • Last modified date

    2020-07-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH26107 PH27532

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI
    IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT
    IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4
    IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI
    IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI70081

       UP20/06/23 P F006

  • R621 PSY UI70082

       UP20/06/23 P F006

  • R622 PSY UI70083

       UP20/06/23 P F006

  • R62H PSY UI70084

       UP20/06/23 P F006

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023