APAR status
Closed as user error.
Error description
While preparing to operationalize zD&T V12.0.4 for traditional operator tasks, like image shutdown, the SCLP console interface becomes unresponsive. Upon investigation, it was discovered that the problem occurred when both the 3270port and intASCIIport are defined to the devmap.
Local fix
To workaround the problem, remove the intASCIIport entry from the devmap and re-IPL the image.
Problem summary
Problem conclusion
Temporary fix
Comments
Remove the port that is not used.
APAR Information
APAR number
PH25517
Reported component name
ZD&T TOOLKIT
Reported component ID
5725G3923
Reported release
C00
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-05-19
Closed date
2021-12-05
Last modified date
2021-12-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"C00"}]