IBM Support

PH20080: POOR RUNTIME PERFORMANCE. THE PROGRAM IS SLOWER THAN PROGRAMS COMPILED WITH PRE-V5.1 VERSIONS OF THE ENTERPRISE COBOL COMPILER

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling and
    running programs compiled with the DYNAM option where the
    program contains nested programs and all CALL statements in the
    program have a literal call target.
    
    RECOMMENDATION TO CUSTOMER: Apply the provided PTF.
    
    PROBLEM SUMMARY: The compiler was unnecessarily generating code
    to set up a table of information that is sometimes needed at
    runtime for dynamic calls to help distinguish between nested
    program calls and external program calls.  However, this table
    is not needed when all the CALL statements in the program have a
    literal call target.
    
    CONCLUSION: The compiler was updated to avoid unnecessarily
    generating the code to set up the table of information for
    dynamic calls when it is not needed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.1 compiling and  *
    *                 running programs compiled with the DYNAM     *
    *                 option where the program contains nested     *
    *                 programs and all CALL statements in the      *
    *                 program have a literal call target.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Poor runtime performance. The program   *
    *                      is slower than programs compiled with   *
    *                      pre-V5.1 versions of the Enterprise     *
    *                      COBOL compiler.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The compiler was unnecessarily generating code to set up a table
    of information that is sometimes needed at runtime for dynamic
    calls to help distinguish between nested program calls and
    external program calls. However, this table is not needed when
    all the CALL statements in the program have a literal call
    target.
    

Problem conclusion

  • The compiler was updated to avoid unnecessarily generating the
    code to set up the table of information for dynamic calls when
    it is not needed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH20080

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-12-09

  • Closed date

    2019-12-16

  • Last modified date

    2020-01-03

  • APAR is sysrouted FROM one or more of the following:

    PH19091

  • APAR is sysrouted TO one or more of the following:

    UI67014 UI67015 UI67016

Modules/Macros

  • IGY8RWTU IGYCCBE  IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP
    IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8
    IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1
    IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R
    IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE
    IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R610 PSY UI67014

       UP19/12/19 P F912

  • R611 PSY UI67015

       UP19/12/19 P F912

  • R612 PSY UI67016

       UP19/12/19 P F912

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023