A fix is available
APAR status
Closed as program error.
Error description
When the DB2 coprocessor is used and the compiler option RULES(NOOMITODOMIN) is specified, the compiler emits the following warning right after the start of WORKING-STORAGE: 000046 WORKING-STORAGE SECTION. ==000046==> IGYDS1158-W **RULES(NOOMITODOMIN)** The first integer in the "OCCURS" clause was omitted. Please note: The integer that was specified was interpreted as the maximum number of elements in the table. The problem does not occur when the DB2 Coprocessor is not used.
Local fix
Ignore the warning until the correcting PTF is applied.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 who compile * * with the SQL option and the * * RULES(NOOMITODOMIN) option. * **************************************************************** * PROBLEM DESCRIPTION: The compiler unexpectedly produces * * error message IGYDS1158-W. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The SQL co-processor produced data description entries that violated the RULES(NOOMITODOMIN) option, which enforces a rule whereby data description entries cannot omit the lower bound of the OCCURS DEPENDING ON clause.
Problem conclusion
RULES(NOOMITODOMIN) processing in the compiler was updated to ignore data description entries produced by the SQL co-processor.
Temporary fix
Comments
APAR Information
APAR number
PH19233
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-14
Closed date
2019-11-26
Last modified date
2020-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI66646
UP19/12/04 P F912
R631 PSY UI66647
UP19/12/04 P F912
R632 PSY UI66648
UP19/12/04 P F912
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: