A fix is available
APAR status
Closed as program error.
Error description
IGYDI5125-U The compilation was terminated due to a compiler error in phase id: "IGYCDIAG"
Local fix
compiling at OPT(0) or turning off NUMCHECK(BIN), or by running the program with NUMCHECK(BIN,MSG) turned on and fixing the invalid data.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling * * programs with NUMCHECK(BIN) containing * * invalid data that is detectable at compile- * * time. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with message * * MSGIGYDI5125-U The compilation was * * terminated due to a compiler * * error in phase id: "IGYCDIAG". * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler was generating NUMCHECK(BIN) messages where the message text, containing the name of the data item and line and statement number on which the invalid data was detected, exceeded an internal limit on the length for message text.
Problem conclusion
The NUMCHECK(BIN) message text was shortened so that the final text of a message would fit within the compiler's internal limit.
Temporary fix
Comments
APAR Information
APAR number
PH12114
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-15
Closed date
2019-05-23
Last modified date
2019-06-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI63207
UP19/05/30 P F905
R621 PSY UI63208
UP19/05/30 P F905
R622 PSY UI63209
UP19/05/30 P F905
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023