A fix is available
APAR status
Closed as program error.
Error description
************************************************* ** Defect Fix Template ** ************************************************* USERS AFFECTED: Users of Enterprise COBOL Vx.x compiling programs at ARCH(10|11) that contain a sequence of consecutive computations involving PACKED-DECIMAL or USAGE DISPLAY data items with differing numbers of digits after the decimal place. PROBLEM DESCRIPTION: Program produces an incorrect result RECOMMENDATION TO CUSTOMER: Apply the provided PTF PROBLEM SUMMARY: At ARCH(10) and ARCH(11), the compiler will often generate Decimal Floating Point (DFP) instructions to perform PACKED-DECIMAL or USAGE DISPLAY arithmetic. When combining truncation operations with alignment-shifting operations (to align the decimal points in data items with different numbers of digits to the right of the decimal point), the compiler was incorrectly generating an incorrect alignment shift, causing an intermediate value to incorrectly become zero. CONCLUSION: The compiler was fixed to generate the correct alignment shifts when using DFP instructions.
Local fix
Compile at OPT(0), ARCH(9) or lower, or ARCH(12)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling * * programs at ARCH(10|11) that contain a * * sequence of consecutive computations * * involving PACKED-DECIMAL or USAGE DISPLAY * * data items with differing numbers of digits * * after the decimal place. * **************************************************************** * PROBLEM DESCRIPTION: Program produces an incorrect result. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** At ARCH(10) and ARCH(11), the compiler will often generate Decimal Floating Point (DFP) instructions to perform PACKED-DECIMAL or USAGE DISPLAY arithmetic. When combining truncation operations with alignment-shifting operations (to align the decimal points in data items with different numbers of digits to the right of the decimal point), the compiler was incorrectly generating an incorrect alignment shift, causing an intermediate value to incorrectly become zero.
Problem conclusion
The compiler was fixed to generate the correct alignment shifts when using DFP instructions.
Temporary fix
Comments
APAR Information
APAR number
PH11948
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-09
Closed date
2019-05-23
Last modified date
2019-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI63207
UP19/05/30 P F905
R621 PSY UI63208
UP19/05/30 P F905
R622 PSY UI63209
UP19/05/30 P F905
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: