IBM Support

PH11948: PROGRAM PRODUCES AN INCORRECT RESULT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • *************************************************
    **            Defect Fix Template              **
    *************************************************
    
    USERS AFFECTED: Users of Enterprise COBOL Vx.x compiling
    programs at ARCH(10|11) that contain a
    sequence of consecutive computations
    involving PACKED-DECIMAL or USAGE DISPLAY
    data items with differing numbers of digits
    after the decimal place.
    
    PROBLEM DESCRIPTION: Program produces an incorrect result
    
    RECOMMENDATION TO CUSTOMER: Apply the provided PTF
    
    PROBLEM SUMMARY: At ARCH(10) and ARCH(11), the compiler will
    often generate
    Decimal Floating Point (DFP) instructions to perform
    PACKED-DECIMAL or USAGE DISPLAY arithmetic. When combining
    truncation operations with alignment-shifting operations (to
    align the decimal points in data items with different numbers
    of
    digits to the right of the decimal point), the compiler was
    incorrectly generating an incorrect alignment shift, causing an
    intermediate value to incorrectly become zero.
    
    CONCLUSION: The compiler was fixed to generate the correct
    alignment shifts
    when using DFP instructions.
    

Local fix

  • Compile at OPT(0), ARCH(9) or lower, or ARCH(12)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling     *
    *                 programs at ARCH(10|11) that contain a       *
    *                 sequence of consecutive computations         *
    *                 involving PACKED-DECIMAL or USAGE DISPLAY    *
    *                 data items with differing numbers of digits  *
    *                 after the decimal place.                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Program produces an incorrect result.   *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    At ARCH(10) and ARCH(11), the compiler will often generate
    Decimal Floating Point (DFP) instructions to perform
    PACKED-DECIMAL or USAGE DISPLAY arithmetic. When combining
    truncation operations with alignment-shifting operations (to
    align the decimal points in data items with different numbers
    of digits to the right of the decimal point), the compiler was
    incorrectly generating an incorrect alignment shift, causing an
    intermediate value to incorrectly become zero.
    

Problem conclusion

  • The compiler was fixed to generate the correct alignment shifts
    when using DFP instructions.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH11948

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-05-09

  • Closed date

    2019-05-23

  • Last modified date

    2019-06-03

  • APAR is sysrouted FROM one or more of the following:

    PH11555

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI63207

       UP19/05/30 P F905

  • R621 PSY UI63208

       UP19/05/30 P F905

  • R622 PSY UI63209

       UP19/05/30 P F905

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: