A fix is available
APAR status
Closed as new function.
Error description
Enable NUMCHECK(BIN) checking on COMP data items even when TRUNC(BIN) is in effect
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6 who want to do * * NUMCHECK(BIN) checking even with * * TRUNC(BIN) in effect. * **************************************************************** * PROBLEM DESCRIPTION: When we implemented NUMNCHECK(BIN), we * * disabled the NUMCHECK(BIN) feature if * * TRUNC(BIN) was in effect, since you * * can't have overpopulated binary items * * with TRUNC(BIN). However, some * * customers want to check anyway to see * * if they can switch to TRUNC(OPT). * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Customer wanted to check for 'overpopulated' data items using NUMCHECK(BIN) even with TRUNC(BIN), but the compiler did not support this.
Problem conclusion
The compiler was changed to enable NUMCHECK(BIN) checking for binary data items (COMP,COMP-4, and USAGE BINARY) even when TRUNC(BIN) is in effect. Note that checking will still not be done for COMP-5 items, because even if a user switches to TRUNC(OPT), COMP-5 items cannot be overpopulated.
Temporary fix
Comments
APAR Information
APAR number
PH11667
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-01
Closed date
2019-05-23
Last modified date
2019-06-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI63207
UP19/05/30 P F905
R621 PSY UI63208
UP19/05/30 P F905
R622 PSY UI63209
UP19/05/30 P F905
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]