Error description

  • ERROR DESCRIPTION:Ø
    Customer has a PBG object with N parts.   and they use stop
    command to stop the entire tablespace.  When stop completed,
    they found that all exsiting parts were in stop status, while a
    new part(N+1) was added and left in RW status.
    stop command used.
    --
    STOP DATABASE(D1ANC01) SPACENAM(S1ANC250) AT(COMMIT)
    --
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DB2 11 for z/OS customers using          *
    *                 Partition By Growth (PBG) table space.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: A new partition was added mistakenly    *
    *                      when any prior partition was stopped.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    There were total 15 existing parts in a PBG table space, which
    can grow more partitions later.  At one point, the entire
    PBG table space was stopped by Db2 STOP DATABASE command. At
    the same time, an insert job was trying to insert more rows
    to the same table space, it ignored the table space being
    stopped, mistakenly added a new partition (#16 in this case).
    

Problem conclusion

  • Db2 code is modified to prevent the growth of the PBG table
    space when any or entire PBG table space partition are
    stopped.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH09317

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    B10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-03-05

  • Closed date

    2019-05-13

  • Last modified date

    2019-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI62992

Modules/Macros

  •    DSNISUPI
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RB10 PSY UI62992

       UP19/05/29 P F905

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 June 2019