A fix is available
APAR status
Closed as program error.
Error description
With APAR PI75055/PTF UI44075 applied, the END-XML token is not generated in the proper location in the SYSADATA syntax tree. It is also possible that any statement before a period could suffer from the same problem of having the last token of the statement not being included in the parse tree for that statement.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling * * programs containing an XML PARSE statement * * and the ADATA and CICS compiler options are * * in effect. * **************************************************************** * PROBLEM DESCRIPTION: Missing ADATA token records and * * incorrect ADATA in parse tree records. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The compiler intentionally skips ADATA token records for certain items generated by the CICS co-processor. Unfortunately, the strategy was being applied too broadly and would sometimes affect code that was not generated by the CICS co-processor.
Problem conclusion
The compiler was updated to avoid inadvertently skipping ADATA token records that are not related to COBOL code generated by the CICS co-processor.
Temporary fix
Comments
APAR Information
APAR number
PH07208
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-01-11
Closed date
2019-01-14
Last modified date
2019-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI60666
UP19/01/30 P F901
R621 PSY UI60667
UP19/01/30 P F901
R622 PSY UI60668
UP19/01/30 P F901
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]