PH04956: THE COMPILER WAS INCORRECTLY GENERATING A CHECK FOR ONLY THE FIRST OF TWO ONE-BYTE LITERALS FOR INSPECT TALLYING STATEMENTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Part of the compiler was making an assumption
    that there was only one literal in the INSPECT statement, which
    meant that when there were 2 literals, the second one was
    ignored. When 3+ literals were present, the compiler called the
    runtime to handle the INSPECT, instead of using generated
    compiler code, so 3+ literals works fine.
    
    USERS AFFECTED: Users of Enterprise COBOL Vx.x compiling
    programs with INSPECT TALLYING statements
    where there were exactly two literals, each
    of length one byte, being tallied.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling     *
    *                 programs with INSPECT TALLYING statements    *
    *                 where there were exactly two literals, each  *
    *                 of length one byte, being tallied.           *
    ****************************************************************
    * PROBLEM DESCRIPTION: The program tallies only the first      *
    *                      literal.                                *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    The compiler was incorrectly generating a check for only the
    first of two one-byte literals for INSPECT TALLYING statements.
    

Problem conclusion

  • The compiler was fixed to generate checks for both of the two
    one-byte literals for INSPECT TALLYING statements.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH04956

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-11-06

  • Closed date

    2018-11-22

  • Last modified date

    2018-12-12

  • APAR is sysrouted FROM one or more of the following:

    PH03358

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI
    IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT
    IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4
    IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI
    IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI59885

       UP18/11/29 P F811

  • R621 PSY UI59886

       UP18/11/29 P F811

  • R622 PSY UI59887

       UP18/11/29 P F811

  • R62H PSY UI59888

       UP18/11/29 P F811

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]