Fixes are available
9.0.0.11: WebSphere Application Server traditional V9.0 Fix Pack 11
9.0.5.0: WebSphere Application Server traditional Version 9.0.5 Refresh Pack
9.0.5.1: WebSphere Application Server traditional Version 9.0.5 Fix Pack 1
9.0.5.2: WebSphere Application Server traditional Version 9.0.5 Fix Pack 2
9.0.5.3: WebSphere Application Server traditional Version 9.0.5 Fix Pack 3
APAR status
Closed as program error.
Error description
"Server reached MaxRequestWorkers" message is issued while idle threads are available.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM HTTP Server * **************************************************************** * PROBLEM DESCRIPTION: One-time message AH00484 "server * * reached MaxRequestWorkers setting..." * * may be issued while idle threads are * * still available. * **************************************************************** * RECOMMENDATION: * **************************************************************** IHS issued the AH00484 message when the limit on the maximum number of threads was reached, no matter how many were idle/available.
Problem conclusion
The code was changed to issue the existing AH00484 message only when all theads have been created and none are idle. AH10159 was added for the cases where AH00484 was mistakenly issued in the past. The fix for this issue is available in 9.0.0.11.
Temporary fix
Comments
APAR Information
APAR number
PH03953
Reported component name
IBM HTTP SERVER
Reported component ID
5724J0801
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-10-11
Closed date
2019-01-08
Last modified date
2019-01-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
IBM HTTP SERVER
Fixed component ID
5724J0801
Applicable component levels
R900 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTJ","label":"IBM HTTP Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Line of Business":{"code":"LOB45","label":"Automation"}}]