A fix is available
APAR status
Closed as program error.
Error description
Missing dependency between July 2018 6.2 COBOL compiler PTF and July 2018 COBOL runtime PTF.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.2 who are * * compiling and running programs using the * * new intrinsic functions HEX-OF and BIT-OF * * but do not have the July 2018 COBOL runtime * * PTF UI57304 (z/OS V2R1), UI57303 (z/OS * * V2R2) or UI57302 (z/OS V2R3) installed on * * their development and production systems. * **************************************************************** * PROBLEM DESCRIPTION: A failure during the link step can * * occur with the following message: * * IEW2456E 9207 SYMBOL IGZX2HEX [or * * IGZX2BIN] UNRESOLVED. MEMBER COULD * * NOT BE INCLUDED FROM THE DESIGNATED * * CALL LIBRARY. * * * * A failure during runtime can occur on * * any system where the program is run. * * e.g. IGZ0153S Program PROG was * * compiled with a level of the compiler * * that requires service to be installed * * on Language Environment. From compile * * unit PROG at entry point FOO at * * compile unit offset +000000FC at * * entry offset +000000FC at address * * 2680A0FC. * **************************************************************** * RECOMMENDATION: Install the July 2018 COBOL runtime PTF on * * all systems where COBOL programs using the * * new HEX-OF and BIT-OF intrinsic functions * * will run and be compiled. * **************************************************************** The July 2018 COBOL 6.2 compiler PTF is missing a pre-req on the July 2018 COBOL runtime PTF, which is needed only for those customers using the new HEX-OF and BIT-OF intrinsic functions.
Problem conclusion
A new COBOL compiler PTF was issued which properly establishes the dependency of the Enterprise COBOL 6.2 compiler on the July 2018 COBOL runtime PTF.
Temporary fix
Comments
APAR Information
APAR number
PH02353
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-30
Closed date
2018-09-04
Last modified date
2018-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI58270 UI58271 UI58272 UI58273
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYWIVP1 IGYWIVP2 IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI58270
UP18/09/06 P F809
R621 PSY UI58271
UP18/10/02 P F809
R622 PSY UI58272
UP18/10/02 P F809
R62H PSY UI58273
UP18/09/06 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: