PH00658: EGL RECORDTYPES VIA GENERATED COBOL RETURNS INCORRECT IO-STATUS OF SQL RECORD

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Its observed that where there are 2 instances of the same record
    type when the first instance is read from the db2 instance then
    the result is not-found.
    The second instance is not touched at all, but the io-indicator
    is set to not-found also on the same instance.
    All records of same type have the IO-status set when one of the
    record-instances is read.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * EGL user who use Recordtypes with generated COBOL            *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * All records of the same type incorrectly have the IO-status  *
    * set when only one of the record-instances is read.           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The issue is fixed in 9511
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH00658

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-07-18

  • Closed date

    2020-07-15

  • Last modified date

    2020-07-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R911 PS1

       UP

  • R950 PSY

       UP

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950"}]

Document Information

Modified date: