A fix is available
APAR status
Closed as program error.
Error description
CBL V6.1 Compiler changes required for Runtime IGZ0060W Message Truncation of high order digit positions; ok at CBL V4.2
Local fix
Problem with IGZXPR2 handling exponents less than -12. To work around the problem, change the COMPUTE statement to avoid the negative exponent. Example: the faulting code: 01 ANSWER PIC 9(1)V9(17) COMP-3. 01 TOT-ACTIV PIC 9(13)V9(2) COMP-3. PROCEDURE DIVISION. *==================* COMPUTE ANSWER = 10 ** -17 * TOT-ACTIV GOBACK. Work-around: Change the COMPUTE statement to avoid the negative exponent: COMPUTE ANSWER = 1 / 10 ** 17 * TOT-ACTIV
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V6.1 users running * * programs compiled with ARITH(COMPAT) that * * contain arithmetic expressions with the * * exponentiation operator (**), where both * * the base and exponent are numeric literals * * and the exponent is an integer less than -1. * **************************************************************** * PROBLEM DESCRIPTION: The exponentiation result might be * * incorrect. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Given the following exponentiation in ARITH(COMPAT) mode, COMPUTE RESULT = BASE ** EXPONENT where - RESULT is a COMP-3(PACKED DECIMAL) data item - BASE is a fixed-point literal - EXPONENT is an integer literal less than -1
Problem conclusion
The compiler was updated to generate the correct information required by the the COBOL runtime to perform the correct exponentiation calculation.
Temporary fix
Comments
APAR Information
APAR number
PH00614
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-07-17
Closed date
2018-07-18
Last modified date
2018-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYWIVP1 IGYWIVP2 IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI58270
UP18/09/06 P F809
R621 PSY UI58271
UP18/10/02 P F809
R622 PSY UI57344
UP18/07/31 P F807
R62H PSY UI58273
UP18/09/06 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023