Error description

  • Setting up Job Log Monitoring for several resources. Forgot to
    set the Job Log Monitoring interval for one of the resources,
    but received msgING350I Improper Job Log Monitoring definition
    found for xxx RSN=14 for resources that were set up correctly
    with JLM.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All SA z/OS V3R4 customers using the Joblog  *
    *                 Monitoring function.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: MsgING350I is issued when Job Log       *
    *                      monitoring definitions exist but no     *
    *                      Job Log Monitor Interval is specified.  *
    *                      The same message can also be issued     *
    *                      when the definitions are found          *
    *                      in an application class.                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Job Log Monitoring definitions should be ignored when no Job
    Log Monitor Interval is specified.
    Job Log Monitoring definitions should be processed correctly
    for application classes without issuing msgING350I with RSN=14.
    

Problem conclusion

  • REXX part INGRJLMP has been modified to correctly process Job
    Log monitoring information.
    
    +------ System Automation for z/OS Version 3 Release 4 --------+
    |                                                              |
    |PROGRAM NUMBER: 5698-SA3                                      |
    |                                                              |
    |TITLE:  Programmer's Reference                  SC34-2650-00  |
    |                                                              |
    |Chapter 2. SA z/OS System Operations Commands                 |
    |Topic:     INGJLM                                             |
    |Subtopic:  Restrictions and Limitations                       |
    |                                                              |
    |Change:                                                       |
    |At the beginning of the subtopic, add the following:          |
    |                                                              |
    |  Dynamically allocated spool output data sets are not        |
    |  supported.                                                  |
    |                                                              |
    +--------------------------------------------------------------+
    +------ System Automation for z/OS Version 3 Release 5 --------+
    |                                                              |
    |PROGRAM NUMBER: 5698-SA3                                      |
    |                                                              |
    |TITLE:  Programmer's Reference                  SC34-2748-00  |
    |                                                              |
    |Chapter 2. SA z/OS System Operations Commands                 |
    |Topic:     INGJLM                                             |
    |Subtopic:  Restrictions and Limitations                       |
    |                                                              |
    |Change:                                                       |
    |At the beginning of the subtopic, add the following:          |
    |                                                              |
    |  Dynamically allocated spool output data sets are not        |
    |  supported.                                                  |
    |                                                              |
    +--------------------------------------------------------------+
    ================================================================
    +------ System Automation for z/OS Version 3 Release 4 --------+
    |                                                              |
    |PROGRAM NUMBER: 5698-SA3                                      |
    |                                                              |
    |TITLE:  Customizing and Programming             SC34-2644-00  |
    |                                                              |
    |Chapter 5. Joblog Monitoring                                  |
    |Topic:     Overview                                           |
    |Subtopic:  Limitations                                        |
    |                                                              |
    |Change:                                                       |
    |Add the following to the subtopic:                            |
    |                                                              |
    |  3. Dynamically allocated spool output data sets are not     |
    |     supported.                                               |
    |                                                              |
    |--------------------------------------------------------------|
    |                                                              |
    |Topic:     Overview                                           |
    |                                                              |
    |Change:                                                       |
    | After the existing text:                                     |
    | The monitoring function is controlled by SA z/OS based on the|
    | definitions of the customization dialog.                     |
    |                                                              |
    |Add the following:                                            |
    |                                                              |
    | Monitoring is automatically started when the job reaches a   |
    | status of UP, ACTIVE or RUNNING. When your job was already   |
    | active at the time you specified the joblog monitoring       |
    | definitions in the customization dialogs then this job must  |
    | be restarted in order to start joblog monitoring for it.     |
    |                                                              |
    +--------------------------------------------------------------+
    ================================================================
    +------ System Automation for z/OS Version 3 Release 5 --------+
    |                                                              |
    |PROGRAM NUMBER: 5698-SA3                                      |
    |                                                              |
    |TITLE:  Customizing and Programming             SC34-2715-00  |
    |                                                              |
    |Chapter 5. Joblog Monitoring                                  |
    |Topic:     Overview                                           |
    |Subtopic:  Limitations                                        |
    |                                                              |
    |Change:                                                       |
    |Add the following to the subtopic:                            |
    |                                                              |
    |  3. Dynamically allocated spool output data sets are not     |
    |     supported.                                               |
    |                                                              |
    |--------------------------------------------------------------|
    |                                                              |
    |Topic:     Overview                                           |
    |                                                              |
    |Change:                                                       |
    | After the existing text:                                     |
    | The monitoring function is controlled by SA z/OS based on the|
    | definitions of the customization dialog.                     |
    |                                                              |
    |Add the following:                                            |
    |                                                              |
    | Monitoring is automatically started when the job reaches a   |
    | status of UP, ACTIVE or RUNNING. When your job was already   |
    | active at the time you specified the joblog monitoring       |
    | definitions in the customization dialogs then this job must  |
    | be restarted in order to start joblog monitoring for it.     |
    |                                                              |
    +--------------------------------------------------------------+
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA46071

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    340

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-09-17

  • Closed date

    2014-11-17

  • Last modified date

    2014-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA75457 UA75458

Modules/Macros

  • INGRJLMP
    

Publications Referenced
SC34265000SC34274800SC34264400SC34271500 

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R340 PSY UA75457

       UP14/11/18 P F411

  • R350 PSY UA75458

       UP14/11/18 P F411

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"340","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 December 2014