IBM Support

OA45657: COMMAND INGRX830 FAILED. RECEIVED RETURN CODE 6 FROM INGHWCMD CPC100Z STATCOM

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Added new CPC's to Policy and run INGAMS REFRESH to pick up the
    changes. The following errors occur:
    AOFA0000 Resolve error: No_HWOPER_task_defined
    AOF200I 10:38:22 : COMMAND INGRX830 FAILED. RECEIVED RETURN CODE
                       6 FROM INGHWCMD CPC300Z STATCOM
    There are enough HWOper's defined to handle the increase in
    CPC's.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All System Automation for z/OS customers of  *
    *                 the releases V3.4 and V3.3, using the        *
    *                 SA-BCPii to monitor and control System z     *
    *                 mainframe processors. All customers of a     *
    *                 GDPS service offering component, which       *
    *                 requires the SA-BCPii of the named System    *
    *                 Automation releases.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: During SA agent startup or INGAMS       *
    *                      REFRESH processing, Clist INGRX830 may  *
    *                      fail with a return code 6. As a result, *
    *                      not all SA-BCPii connections to the     *
    *                      defined processors may become active,   *
    *                      or can be activated later by the        *
    *                      SA-BCPii connection monitor or the GDPS *
    *                      HMC monitor routine.                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Hardware validation and monitoring Clist INGRX830 fails with RC
    6. Required SA-BCPii connections may not be activated.
    

Problem conclusion

  • HWOPER tasks, which are actually assigned to a processor are
    fully initialized, supernumerous defined HWOPER tasks are
    started, but remain uninitialized. In case of an INGAMS REFRESH
    that adds processors to the configuration, such available HWOPER
    tasks fail to be fully initialized. As a result, the SA-BCPii
    session initialization for one or multiple processors may not
    function as expected, although the number of HWOPERs matches the
    number of the defined processors + 1, which is the required
    HWOPER task count.
    
    The following clists have been changed to make sure the
    HWOPER tasks, that wait to be assigned for work, are now
    initialized correctly:
    
    - INGRX805: HWOPER task initial clist.
    - INGRX810: SA-BCPii front end command.
    - INGRVX80: HW validation HW command handler.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA45657

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    340

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-07-16

  • Closed date

    2014-08-19

  • Last modified date

    2014-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA74586 UA74587

Modules/Macros

  • INGRVX80 INGRX805 INGRX810
    

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R330 PSY UA74586

       UP14/08/21 P F408

  • R340 PSY UA74587

       UP14/08/21 P F408

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"340","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: