IBM Support

OA45366: MSGDWO378E ISSUED WHEN MONITOR ROUTINE FOR MTR RESOURCE CONTAINS THE NORMAL PIPE SEPARATOR IN THE REXX CODE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a REXX Clist containing the normal NetView PIPE separator
    within the clist's code when SAzOS calls the routine defined
    in the 'MONITOR INFO' Policy a DWO378E will be produced.
    Ex:
    DWO378E LABEL STRING IS TOO LONG, GREATER THAN 8 CHARACTERS
    IN LENGTH: '>ABCDEFGH'.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All SA z/OS V3R3 and V3R4 customers.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: INGMON command can fail with message    *
    *                      DWO378E and/or DWO364E, DWO362E.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When characters are used which are identical to the NetView
    PIPE separator (i.e. |) then INGMON/AOFRUMTR can fail with
    PIPE errors.
    

Problem conclusion

  • REXX module AOFRUMTR has been modified to use an nonprintable
    PIPE stage separator.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA45366

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    330

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-06-04

  • Closed date

    2014-06-25

  • Last modified date

    2014-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA73983 UA73984

Modules/Macros

  • AOFRUMTR
    

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R330 PSY UA73983

       UP14/06/28 P F406

  • R340 PSY UA73984

       UP14/06/28 P F406

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"330","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 July 2014