IBM Support

OA44912: SMALL ENHANCEMENTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Small Enhancements
    .
    For cmd INGRDS IMPORT tdutl01 DSNAME('TEST.USER.DATA(TEST01)'):
    Quotes around DSNAME specification for the INGRDS IMPORT command
    should not result in
    DSI650I INVALID SYNTAX: '''...)'''
    ING338I Function or command INGRCRDS failed, RC=226
    REASON=IMPORT QSAM failed for...
    Also resolved the following issue:
    AOF608E REXX Function package INGRXFPG not installed
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All SA z/OS V3R3 and V3R4 customers.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: see description below...                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    SA 3.3, 3.4:
    o INGTIMER should have an optional parameter (AVAILABLE) to
    enforce that the command will be rejected unless the subsystem
    is AVAILABLE (status UP or ENDED).
    o Auxiliary Storage Shortage Recovery needs to be enhanced
    and messages IRA250I, 252I, 260E, 262I, 265I need to be added
    to +SA_PREDEFINED_MSGS.
    
    SA 3.4:
    o Adjustment to Joblog Monitoring due to z/OS changes
    to the resource name of the SAF check.
    o Customization Dialog command 'CN' on panel AOFGDYNM (Message
    Processing) can incorrectly display the name of a class when
    entered against a line where in fact no data is inherited.
    o Enhance INGPW to allow for the generation of mixed case
    passwords.
    o AOFRCMTR should be enhanced to store the message that caused
    the AOFRCMTR call in the SAFE named AOFMSAFE.
    o Officially introduce and document the INGENQ command that
    allows customers to perform z/OS macros ENQ and DEQ.
    o Allow any REXX program that was scheduled via the SAz Batch
    procedure AOFRYCMD to retrieve the originating jobname and
    userID via task globals AOFRYCMD_JOBNAME and AOFRYCMD_USERID.
    o Importing an RDS table via INGRDS should work regardless
    whether a DSN was specified with or without quotes.
    o When calling INGALERT with Code3=USR (for INFORM=USR), a
    'Value Returned' of 'ERROR' should not result in msgING144I,
    indicating CDEMATCH FOR xyz INGALERT WITH CODES abc RETURNED
    INVALID VALUE:ERROR.
    For INFORM=USR, there should be no restriction for possible
    specifications in field 'Value Returned'.
    

Problem conclusion

Temporary fix

Comments

  • Changes have been made to implement the enhancements listed
    above.
    Refer to the ++HOLD DOC for documentation updates.
    

APAR Information

  • APAR number

    OA44912

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    340

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-04-01

  • Closed date

    2014-07-18

  • Last modified date

    2014-10-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA74230 UA74231 UA74232 UA74233

Modules/Macros

  • AOFB099  AOFFCREL AOFFVTDB AOFHELPS AOFRCMTR AOFRSMTR AOFT0MSA
    AOFT0MSX AOF95    EVJRVCMD HSAPSTFT ING#ENQ  INGBX0VN INGCBC00
    INGCBX00 INGCGPW  INGENVSA INGHPREF INGHSYS  INGPNJLM INGPNJLU
    INGRCRDS INGRVALT INGRXFPG INGRX742 INGRYTIM INGTXFPG INGY132
    

Publications Referenced
SC34257602SC34265000SC34264400SC34264500SC34264800

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R330 PSY UA74230

       UP14/07/22 P F407

  • R331 PSY UA74231

       UP14/07/22 P F407

  • R340 PSY UA74232

       UP14/07/22 P F407

  • R341 PSY UA74233

       UP14/07/22 P F407

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"340","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
08 October 2014