Fixes are available
APAR status
Closed as program error.
Error description
The compiler produces an internal compiler error when compiling the following test case: $cat test.f90 MODULE marker_class IMPLICIT NONE TYPE :: collision_type INTEGER :: markerNumber2 TYPE( collision_type ), POINTER :: previous => NULL() END TYPE Collision_type TYPE :: slave_type REAL, DIMENSION(:,:,:,:), ALLOCATABLE :: vel TYPE( collision_type ), POINTER :: collision => NULL() END TYPE slave_type TYPE :: marker_type TYPE( slave_type ), POINTER :: slave => NULL() TYPE( collision_type ), POINTER :: collision => NULL() END TYPE marker_type TYPE( marker_type ), POINTER :: marker => NULL() CONTAINS SUBROUTINE initSlave IMPLICIT NONE ALLOCATE(marker%slave) END SUBROUTINE SUBROUTINE mergeMarkerLocal IMPLICIT NONE INTEGER :: markerNumber marker%collision%markerNumber2 = markerNumber END SUBROUTINE mergeMarkerLocal END MODULE marker_class USE marker_class IMPLICIT NONE NULLIFY(marker%collision%previous) end $
Local fix
N/A
Problem summary
USERS AFFECTED: Users having derived type objects with allocatable/pointer components in their applications may experience this problem. PROBLEM DESCRIPTION: Compilation may fail due to Internal Compiler Error.
Problem conclusion
The compiler has been fixed and will no longer produce an Internal Compiler Error for the above scenario.
Temporary fix
Comments
APAR Information
APAR number
LI76621
Reported component name
XL FORTRAN LINU
Reported component ID
5724X1600
Reported release
D10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-02-06
Closed date
2012-05-23
Last modified date
2012-05-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
XL FORTRAN LINU
Fixed component ID
5724X1600
Applicable component levels
RD10 PSY
UP