  • Closed as program error.

Error description

  • With V9.0.0.2, the Docker containers can be started up with
    "CONFIGURE_MODE=Vault" parameter to pull configurations stored
    in Vault. However, for the Java Health Center configurations
    included in vaultConfigure.sh from the Transaction server
    container, the enableHealthCenter property is incorrectly
    checked if set to false to enable Java Health Center:
    
    if [ "$enableHealthCenter" != "null" ] && [
    "$enableHealthCenter" != "true" ]; then
    
    As a result, configuring Java Health Center to be enabled
    through Vault will not enable Java Health Center.
    

Local fix

  • You can copy the vaultConfiguration.sh and correct the changes
    instead of building it into docker to fix this issue as a
    workaround.
    

Problem summary

  • USERS AFFECTED:
     V9.0.0.2+
    
    PROBLEM ABSTRACT:
    The enableHealthCenter property is used incorrectly in
    vaultConfigure.sh for Transaction server container
    
    BUSINESS IMPACT:
    Cannot enable Health Center
    
    RECOMMENDATION:
    

Problem conclusion

  • Correct the condition in vaultConfiguration.sh
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR59425

  • Reported component name

    WC BUS EDITION

  • Reported component ID

    5724I3800

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-04-16

  • Closed date

    2019-01-03

  • Last modified date

    2019-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WC BUS EDITION

  • Fixed component ID

    5724I3800

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYSYL","label":"WebSphere Commerce Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Line of Business":{"code":"LOB31","label":"WCE Watson Marketing and Commerce"}}]

Document Information

Modified date:
11 December 2021