IBM Support

JR54588: Facet values are displayed using the default sequencing or missing image data after applying JR53547.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After applying JR53547, the
    SELECT_FACET_VALUE_IMAGE_AND_SEQUENCE query was updated to also
    retrieve unit of measurement data for the facet values. However,
     the way the query is constructed requires that you have unit of
     measurement data associated to the facet value for the facet
    data to be returned by this query. As a result, if you don't
    have unit of measurement data associated to a given facet, then
    the facet's image and sequence data will not be returned. This
    will cause the facet to use the default sequencing behavior (by
    count) as well as not have image data for display.
    

Local fix

Problem summary

  • USERS AFFECTED:
    WebSphere Commerce V7 users with JR53547 applied.
    
    PROBLEM ABSTRACT:
    Facet values are displayed using the default sequencing or
    missing image data after applying JR53547.
    
    BUSINESS IMPACT:
    Shoppers do not see facet values in the defined sequence and
    image data for the given facet value.
    
    RECOMMENDATION:
    

Problem conclusion

  • Update SELECT_FACET_VALUE_IMAGE_AND_SEQUENCE query to not
    require unit of measurement data (QTYUNITDESC) for the facet
    value.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR54588

  • Reported component name

    WC BUS EDITION

  • Reported component ID

    5724I3800

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-10-23

  • Closed date

    2015-12-07

  • Last modified date

    2015-12-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WC BUS EDITION

  • Fixed component ID

    5724I3800

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYSYL","label":"WebSphere Commerce Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB31","label":"WCE Watson Marketing and Commerce"}}]

Document Information

Modified date:
11 December 2021