IBM Support

JR51416: Missing JNDI Name in GUI Config Client on Transports Inbound and Outbound Page

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When transports threads are updated from configuration manager
    then instance.xml/ wc-server.xml overwrites the existing entries
     in Instance.xml/wc-server.xml. The root cause of missing JNDI
    name is that configuration manager panel leaves JNDI name as
    blank
    

Local fix

  • Either update the instance.xml manually or update the JNDI name
    manually in GUI Configuration Manager
    

Problem summary

  • USERS AFFECTED:
    Users who tries to increase the threads for
    inboundListener for MQ for enabled transport
    
    PROBLEM ABSTRACT:
    Missing JNDI Name in GUI Config Client on Transports Inbound and
    Outbound Page
    
    BUSINESS IMPACT:
    Change in threads "Parallel
    Inbound listener" may unable to listen and corresponding process
    are not honoured
    

Problem conclusion

  • Change the logic not to overwrite the JNDI name to empty when
    saving the changes
    -------------------------------------------------------------
    The latest available maintenance information can be obtained
    from the Recommended Fixes for WebSphere Commerce technote:
    http://www.ibm.com/support/docview.wss?rs=3046&uid=swg21261296
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR51416

  • Reported component name

    WC BUS DEV ED W

  • Reported component ID

    5724I3900

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-10-02

  • Closed date

    2014-11-25

  • Last modified date

    2014-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WC BUS DEV ED W

  • Fixed component ID

    5724I3900

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Product":{"code":"SSYT2H","label":"WebSphere Commerce Developer Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB31","label":"WCE Watson Marketing and Commerce"}}]

Document Information

Modified date: