Fixes are available
APAR status
Closed as program error.
Error description
Communications Server for Windows --------------------------------- After a mainframe IPL causes a reset of PU and LUs, SLI_OPEN and RUI_INIT calls are rejected with SLI_LOGIC_ERROR and COMMAND_COUNT_ERROR, respectively.
Local fix
Problem summary
USERS AFFECTED: All using the LUA API. PROBLEM DESCRIPTION: See error description, above. PROBLEM SUMMARY: When the following sequence of events occurs during the mainframe IPL: << UNBIND RQ >> UNBIND +RSP >> NOTIFY RQ (SLU disabled) (no NOTIFY +RSP) << ACTPU RQ >> ACTPU +RSP << ACTLU RQ >> ACTLU +RSP then CSWIN fails to reset its internal LU tracking correctly, so subsequent SLI_OPEN/RUI_INIT calls are rejected for this LU. A subsequent DACTPU/ACTPU/ACTLU may cause the LU to be properly reset so it becomes usable again.
Problem conclusion
The root cause has been identified and corrected.
Temporary fix
appn.sys
Comments
APAR Information
APAR number
JR49449
Reported component name
COMM SERV NT 6.
Reported component ID
5639F2503
Reported release
613
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-02-25
Closed date
2014-03-21
Last modified date
2014-03-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COMM SERV NT 6.
Fixed component ID
5639F2503
Applicable component levels
R613 PSY
UP