Error description
Cust modified/changed an IP FILTER to TNSERVER profile using the Node Configuration Utility and applied the change to an active node causing the TNSERVER functionality to stop. . PCS5954I : START NODE is issued from user xxx, station yyyy. PCS3001E : Message logging function of Communication Server detected a system error - 1813. PCS5501E : Nodeinit call for start_tn3270 returned tn3270_START_FAILED_ERROR.
Local fix
RESTART NODE.
Problem summary
The TN3270 Server terminates when adding a filter and applying the changes to an active node.
Problem conclusion
The TN3270WN.EXE module was changed to ensure the TN3270 server doesn't go down and the status of the TN3270E server is displayed properly when adding a filter and applying changes to an active node.
Temporary fix
SUPPLIED ON 6/30/2010
Comments
APAR Information
APAR number
JR46209
Reported component name
COMM SERV NT 6.
Reported component ID
5639F2503
Reported release
613
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-04-02
Closed date
2013-04-02
Last modified date
2013-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
TN3270WN
Fix information
Fixed component name
COMM SERV NT 6.
Fixed component ID
5639F2503
Applicable component levels
R613 PSY
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSHQNF","label":"Communications Server for Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"613","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 October 2021