JR42978: TEAMWORKS 6.X TO BPM 7.5.1 MIGRATION FAILS TO MIGRATE ACTIVE INSTANCES IN SOME CASES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • migration can map the numeric id to the UUID successfully, but
    it try to insert the "ID<POType.BpdEvent>" to the database
    directly, it will call object toString, which return the
    "BpdEvent.96dc8fb4-8565-4883-991c-cf532ab86f94" for example, it
    longer than the length defined at the database, it can cause the
    "Invalid column type" SQL exception.
    
    Oracle show this exception is very misleading, because it's not
    the type invalid, the length violation actually.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  User migrating from Teamworks 6.x with in   *
    *                  flight instances.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION: SQL exception is thrown when            *
    *                      attempting to migrate from Teamworks    *
    *                      6.x.                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Migration can map the numeric id to the UUID successfully for
    the table LSW_INST_MSG_EXCL. But it tries to insert the
    "ID<POType.BpdEvent>" to the database directly, and it will
    call object toString, which then returns a string that is
    longer than the length defined at database, thus can cause
    the "Invalid column type" SQL exception.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    JR42978

  • Reported component name

    BPM STANDARD

  • Reported component ID

    5725C9500

  • Reported release

    750

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-06-01

  • Closed date

    2012-07-26

  • Last modified date

    2012-07-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R750 PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTDH","label":"IBM Business Process Manager Standard"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5"}]