A fix is available
APAR status
Closed as program error.
Error description
Timeout activity in an Eventhandler with a specified Date and Repeat causes process assertion violation. . Customer is experiencing a problem in using a timeout activity in a BPEL process Eventhandler. The problem is that when in WID we set the 'Details' of a timeout with a Date AND we also set the 'Repeat' with an interval written in Java. We get the following exception at runtime when the timeout triggers: [12/15/11 10:35:00:700 CET] 0000005a TraceBPE E com.ibm.bpe.util.Assert.assertion(Assert.java:64) -------------------------- Assertion Failure ---------------------------- [12/15/11 10:35:00:700 CET] 0000005a TraceBPE E com.ibm.bpe.util.Assert.assertion(Assert.java:65) [12/15/11 10:35:00:700 CET] 0000005a TraceBPE E com.ibm.bpe.util.Assert.assertion(Assert.java:66) Assertion violation !(useRepeatSpec == false) in method >> com.ibm.bpe.engine.BpelAlarmHandler.evaluateJavaEHAlarmExpressio n(BpelAlarmHandler.java:989)<< [12/15/11 10:35:00:700 CET] 0000005a TraceBPE E com.ibm.bpe.util.Assert.assertion(Assert.java:67) [12/15/11 10:35:00:700 CET] 0000005a TraceBPE E com.ibm.bpe.util.Assert.assertion(Assert.java:68) ---------------------------------------------------------------- [12/15/11 10:35:00:856 CET] 0000005c BpelEngine I CWWBE0110E: An error occurred during the evaluation of a timeout expression for an event handler. Expression name '10_0'. com.ibm.bpe.util.ProcessAssertionError: Assertion violation !(useRepeatSpec == false) in method >> com.ibm.bpe.engine.BpelAlarmHandler.evaluateJavaEHAlarmExpressio n(BpelAlarmHandler.ava:989_ <<
Local fix
Problem summary
Problem fixed
Problem conclusion
Fix will be included in V7511
Temporary fix
Comments
APAR Information
APAR number
JR41714
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-01-18
Closed date
2012-03-12
Last modified date
2012-03-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
R751 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1"}]
Document Information
Modified date:
07 October 2021