IBM Support

IZ85369: Release of CICS Explorer v1.0.1

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • This APAR was raised to track an update to the CICS Explorer,
    version 1.0.1.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Explorer Users                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Release of CICS Explorer v1.0.1         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR tracks the release of CICS Explorer version 1.0.1.
    
    This update provides the following new enhancements:
    
    * The new System z/OS perspective containing a set of new views
    to help you manage your System z artifacts. These views are
    named Data Sets, Jobs, z/OS Unix Files, and Console.
    * The ability to export and import system connection details
    using the new Connection Export/Import page in the Connection
    Preferences view. You can export your connections as an .xml
    file. This file can be edited, shared with other users, and
    imported into other CICS Explorer instances.
    * A new breadcrumb trail is displayed in the editor view that
    shows the location of a resource.
    * The ability to view system initialization table (SIT)
    parameters, SIT overrides, or a combination of both. You cannot,
    however, see changes in the values of parameters that were made
    after startup using system programming interface commands.
    * Four new Operations views have been added in this version.
    These views are named CMAS to CMAS Links view, Journal Models
    view, Journal Names view, and Stream Names view.
    * One new Administration view named CMAS to CMAS Link
    Definitions view.
    * A System z/OS Quick Tips section has been added to the
    documentation. This topic is intended to provide short answers
    to frequently asked questions about the System z/OS perspective.
    
    The What's New topic in the CICS Explorer help documentation
    describes the new and changed items in more detail. To display
    the topic, click Help > Help Contents > What's new in version
    1.0.1.
    
    The following defects have also been fixed as part of this
    update:
    
    1187: All RegionGroupDefinitions are incorrectly nested beneath
    all RegionGroupDefinitions in the CICSplex Repositories View
    when using a Data connection
    1425: Excessive Password Prompting and connecting in CICS
    Explorer
    4901: Error on Create XXXDefinition Wizard when a Resource Group
    is selected before the wizard opened
    7022: INSTALL failures in CREATE cmd not properly returned in
    CNX msg
    7436: Error numbers should translate to text
    8687: UI delegate contributions are not disabled after
    performing an operation
    9271: Plugin perspectives not cleaned up when plug-in uninstalle
    9417: Combination of externalized and unexternalized colons
    9759: Error messages not appearing correctly in fields on editor
    10524: Explorer Administration - New dialogs and folding of name
    10604: Attempt to quiesce WLM target MAS gives RESPONSE(FAILED)
    REASON(EXCEPTION)
    10617: Accessibility issue with N/A values
    10913: Explorer links to the InfoCenter don't honour/use my
    default browser
    11726: Connections preferences page "Could not accept changes"
    error box
    11834: Attribute column names in the Event Processing view
    should be the CPSM short names
    12038: Inadequate user feedback given in the case the an
    exported EP adapter has a schema not supported by CICS.
    12274: Beta forum: Port Number:  place on the Connections setup
    pop-up should be bigger.
    12437: Clarify error when data pasted into wrong columns for
    COBOL
    12744: Bundle Projects export as ASCII and not Binary
    12994: CNX0604E: Delete Resource Group Definition "TESTGRP1"
    from "CICSPLX1" failed
    13556: Selecting an information source for half/full word types
    results in incorrect length
    13600: Multiple Workloads (same name different owner) not
    differentiated in CICSplex Explorer window
    13602: CICSplex Explorer Workload Routers list of regions
    incorrect when multiple instances of Workload
    13617: Explorer CICSplexes view returns no data and "CNX0201I No
    context" when should return CMASs for CICSplex(es)
    13618: Description of "greyed-out" CICSplex Repository needs to
    include "no connection to MP CMAS"
    14686: Atom Configuration schema not catching problems created
    by the atom configuration editor
    14690: Atom Configuration Editor seems to have globalisation
    problems
    14696: Default URI in Atom Config Wizard accepts tabs
    14867: CICS SM Operations folder of available views contains
    non-Operations views
    14877: CICS trying to connect to undefined CICS connection in a
    new workspace
    14881: explorer validator not functioning correctly for filter
    data type CHARZ
    14929: Modified CNX0222W should include the resource object in
    the message
    15075: SMSS Explorer "CICSplex Repositories" help is now
    out-of-date
    15150: First character ignored when adding new connection
    credential
    15228: Atom configuration file Wizard and Editor defects
    15243: Event binding option appears twice in the "New" context
    menu
    15244: Validation of Bundle Project z/OS exporter not trigger on
    load
    15403: URIMAP application command option on INVOKE SERVICE does
    not work in information sources
    15434: Emitted business information table has incorrect columns
    in the EBE
    15451: Invalid field validation on transaction definition object
    transaction service field
    15459: Selection of Transactional inconsistent for EP adapters
    15467: Can't shutdown multiple CICS Regions at the same time via
    the Explorer
    15474: Event Binding editor is inconsistent with replacing space
    characters with _ characters
    15489: Minor changes to enhance CNX0106E
    15503: XMLTRANSFORM bundle creation doesn't sit at a logical
    point in the menu hierarchy
    15504: Description in "Import XML transform source" wizard is
    wrong
    15533: SMSS connected Explorer returns INVALIDPARM PARM if
    select a Respository in Repositories view
    

Problem conclusion

  • Version 1.0.1 has been released for IBM CICS Explorer. This is
    available via two options:
    
    1. Update the CICS Explorer from within the CICS Explorer using
    the IBM-hosted Update-Site.
    2. Download the update from Fix Central to be installed locally
    into the CICS Explorer.
    
    Updating using the Update-Site
    
    Important: Please note the location for the IBM hosted
    update-site has moved. Please follow the instructions below to
    add the new update-site location to the CICS Explorer.
    
    * Start CICS Explorer.
    * Select Help -> Software Updates... from the main menu.
    * Click the Available Software tab and click Manage Sites...
    * If an existing update-site pointing to the old location is
    present remove it by selecting it and click the Remove button.
      The previous URL was:
      http://download.boulder.ibm.com
      /ibmdl/pub/software/htp/cics/updates/explorer/
      (concatenate the URL above).
    * Add the new location by clicking the Add... button and enter
    the following URL into the Location text box:
      http://download.boulder.ibm.com
      /ibmdl/pub/software/htp/cics/updates/explorer/1.0/latest/
      (concatenate the URL above).
    * Note: This update-site above will look for any update to
    Version 1.0 of the CICS Explorer, including new modification
    levels such as 1.0.1. This is the recommended update-site to
    use. To explicitly choose updates for a specific modification
    level you can choose:
      http://download.boulder.ibm.com
      /ibmdl/pub/software/htp/cics/updates/explorer/1.0/1.0.1/
      (concatenate the URL above). This will contain all updates for
    1.0.1.x but any new modification levels in the future will not
    be included. Using the 'latest' update-site will ensure all
    updates for Version 1.0 will be available.
    * Once you've added the update-site you want to the Location
    text box click the OK button.
    * Click OK to leave the Available Software Sites dialog and
    return to the Software Updates and Add-ons dialog.
    * Click the Installed Software tab and click Update...
    * An update should be found for the CICS Explorer, verify that
    the update version is 1.0.1.0_201009220955 or higher.
    * Click Finish to install the update.
    * Once the update has completed you'll be prompted to restart
    the CICS Explorer for the update to take effect. Click Yes.
    * Optionally, verify that the CICS Explorer version has been
    updated:
      * Select Help -> About IBM CICS Explorer from the main menu
    and note the version, it should be 1.0.1 or higher.
    
    Note: The version of the CICS Explorer may now be higher than
    1.0.1 as the update updates to the latest version of the CICS
    Explorer. All updates are cumulative so the latest version
    contains this update as well as any later updates.
    
    The CICS Explorer is now up-to-date with this update installed,
    and no further action is necessary.
    
    If no update was found using the above steps, verify that the
    version of the CICS Explorer is prior to 1.0.1.
    
    To do this select Help -> About IBM CICS Explorer from the main
    menu and note the version currently installed.
    
    If the version is lower than 1.0.1 and no update was found, then
    make sure that the IBM-hosted Update Site is installed (it is by
    default):
    * Select Help -> Software Updates...
    * Click the Available Software tab.
    * Click the Manage Sites... button.
    * Make sure there is an entry with name "CICS Explorer" and a
    location of:
      http://download.boulder.ibm.com
      /ibmdl/pub/software/htp/cics/updates/explorer/1.0/latest/
      (concatenate the URL above).
    * If the entry is not there, or incorrect, delete the existing
    entry, and click Add Site... and add the url above into the text
    box and click OK.
    * Retry updating the CICS Explorer as already described further
    up.
    
    Updating using IBM Fix Central
    To update the CICS Explorer using the Fix Central follow the
    instructions below:
    
    * Open a browser and go to the Fix Central website:
    http://www.ibm.com/support/fixcentral/
    * Select WebSphere from the Product Group drop-down menu.
    * Select CICS Explorer from the Product drop-down menu.
    * Select All from the Installed Version drop-down menu.
    * Select All (or your platform) from the Platform drop-down menu
    * Click Continue.
    * Select the "APAR or SPR" option and enter IZ85369 into the
    text box next to it.
    * Click Continue.
    * Select the corresponding Fix Pack's checkbox and click
    Continue.
    * Select the desired download mechanism and click Continue.
    * Optionally, click on the readme to view it.
    * Download the Update Site zip.
    
    Once the download has completed:
    
    * Start CICS Explorer.
    * Select Help -> Software Updates... from the main menu.
    * Click the Available Software tab.
    * Click Add Site...
    * Click the Archive... button.
    * Find the update-site zip just downloaded, and click Open.
    * Click OK to add that update-zip as an available update.
    * Click the Installed Software tab and click Update...
    * The update should be found for the CICS Explorer, verify that
    the update version is 1.0.1.0_201009220955.
    * Click Finish to install the update.
    * Once the update has completed you'll be prompted to restart
    the CICS Explorer for the update to take effect. Click Yes.
    * Optionally, verify that the CICS Explorer version has been
    updated:
      * Select Help -> About IBM CICS Explorer from the main menu
    and note the version, it should be now 1.0.1.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IZ85369

  • Reported component name

    CICS EXPLORER V

  • Reported component ID

    5655S9701

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-23

  • Closed date

    2010-09-24

  • Last modified date

    2010-09-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS EXPLORER V

  • Fixed component ID

    5655S9701

Applicable component levels

  • R100 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC8GK3","label":"Explorer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: