Error description
Environment: All platforms, known to be an issue at 621, 622 (including 622 FP2) This is specifically the CLI component and it's method of parsing the string. Problem Description: When a situation's SITINFO includes a string which contains a KEYWORD such as SEV, the SITINFO data isn't parsed properly and thus the creation of the situation fails. Looking at this SITINFO: <SITINFO><![CDATA[ATOM=KAMMVSEVNT.MSGTEXT;SEV=Unknown;~]]></SITI NFO> The table name KAMMVSEVNT contains the KEYWORD SEV. We fail on the create because the parser is expecting an equal after the SEV in the table name kammvSEVnt. If one of the letters is removed, the create works. Detailed Recreation Procedure: There is no need to install the KAM support to recreate and test. You can just export an existing sit and then modify the ATOM field and add in the chars SEV, TFWD, TDST, etc. <SITINFO><![CDATA[ATOM=KAMMVSEVNT.MSGTEXT;SEV=Unknown;~]]></SITI NFO> Again, if you just remove either the S or V or E from the table name, the sit imports just fine. I am running this on 622 FP2.
Local fix
Edit the SITINFO data - remove the ATOM field. Create/import the situation and then edit the situation via the sit editor and add the Display Item back.
Problem summary
tacmd createsit from an xml file fails when SITINFO contains spurious keyword substrings like "SEV"
Problem conclusion
Proper check of keywords substrings have been implemented. The fix for this APAR is included in the following maintenance vehicle: | fix pack | 6.2.1-TIV-ITM-FP0004 | fix pack | 6.2.2-TIV-ITM-FP0004
Temporary fix
Comments
APAR Information
APAR number
IZ84215
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-09-02
Closed date
2010-10-08
Last modified date
2011-03-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R621 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622"}]
Document Information
Modified date:
30 December 2022