Error description
* * APAR Type: Field Approver Initials: RP Severity: 2 Reported Release: 621 Compid: 5724C04MS Tivoli Enterprise Management Server ABSTRACT: HOT-STANDBY SYNCHRONIZATION SKIPS OFF-LINE NODES PROBLEM DESCRIPTION: When the HUB and Mirror TEMS start-up synchronization will occur so that the Mirror matches the current HUB in the event of a switch. But node status will not be sent if the node is currently off-line. If there is already a record of the node at the mirror then this will have no impact if a switch occurs. But if the mirror is not aware of this node because it is new, then a record for the node will not be created at the mirror. If a switch occurs, offline node status events will not be generated for these nodes resulting no notification of an off-line node. RECREATE INSTRUCTIONS: Shutdown the mirror. Then attach a new agent to the HUB or an RTEMS. Stop the agent. Bring up the mirror. After the mirror synchronizes shutdown the HUB. When the mirror becomes the primary HUB connect a TEP/TEPS and verify that the MS_Offline situation does not report the new agent being off-line.
Local fix
Problem summary
If a new node comes on-line in a Hot-Standby environment with the mirror down and the node is off-line when the mirror comes up, the node will not be replicated.
Problem conclusion
Allow off-line nodes to be replicated by Hot-Standby. The fix for this APAR is included in the following maintenance vehicle: | fix pack | 6.2.1-TIV-ITM-FP0004 | fix pack | 6.2.2-TIV-ITM-FP0004
Temporary fix
Comments
APAR Information
APAR number
IZ81182
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
621
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-07-29
Closed date
2010-10-15
Last modified date
2011-03-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R621 PSY