Readmes are available
IBM Tivoli 4.0.0-TIV-SSM-FP0010
IBM Tivoli 4.0.0-TIV-SSM-FP0011
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 12 README 4.0.0-TIV-SSM-FP0012
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 13 README 4.0.0-TIV-SSM-FP0013
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 14 README 4.0.0-TIV-SSM-FP0014
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.14-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.0.14-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.0.14-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.0.14-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 5 README 4.0.0.14-TIV-SSM-IF0005
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 6 README 4.0.0.14-TIV-SSM-IF0006
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 7 README 4.0.0.14-TIV-SSM-IF0007
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 8 README 4.0.0.14-TIV-SSM-IF0008
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.15-TIV-SSM-IF0001
APAR status
Closed as program error.
Error description
The scenario is the following: - create on Windows a monitor for the file c:\tmp\file.txt subagent load logmonx logmonx reset logmonx logfile="c:\tmp\file.txt" logmonx updateinterval=60 logmonx create - the monitor works fine - try to monitor the same file using a forward-slash character instead of back-slash one subagent load logmonx logmonx reset logmonx logfile="c:\tmp/file.txt" logmonx updateinterval=60 logmonx create - the monitor no more works.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: Users of LogMonX on Windows. **************************************************************** PROBLEM DESCRIPTION: LogMonX should support forward slashes in file paths on Windows as most Windows commands do **************************************************************** RECOMMENDATION: Upgrade to Fix Pack 10 for SSM 4.0. ****************************************************************
Problem conclusion
Windows does mostly support forward slash already. LogmonX had one minor bug in its globbing logic which accepted backslash only on Windows. This has now been generalized to support forward and backslash. The fix for this APAR is contained in the following maintenance packages: | fix pack | 4.0.0-TIV-SSM-FP0010
Temporary fix
Comments
APAR Information
APAR number
IZ78043
Reported component name
NETCOOL SYS SVC
Reported component ID
5724P4300
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-06-24
Closed date
2010-07-01
Last modified date
2010-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL SYS SVC
Fixed component ID
5724P4300
Applicable component levels
R400 PSN
UP
Document Information
Modified date:
01 July 2010