IZ76004: SITUATION NOT RUNNING AFTER TEMS RESTART

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After re-cycling multiple rTEMS, situations fail to start
    because an
    agent has switched during the restart and the situation has been
    deleted
    from the situation description table of the rTEMS that the agent
    switched away from.  When the agent switches back to that rTEMS,
    the
    situation cannot start.
    
    
    RECREATE INSTRUCTIONS:
    
    Not recreatable without special wait timers inserted into the
    product to
    force the exact sequence of events to occur.
    

Local fix

  • Start each rTEMS sequentially and allow to complete its start-up
    before proceeding with the next rTEMS.
    

Problem summary

  • After a remote management server is restarted and agents have
    connected back, situations fail to start for some agents.
    

Problem conclusion

  • If the timing is just right between the agent switch to
    secondary and the recycling management servers' heartbeat
    processing, the access list cache won't be cleared at the HUB
    management server for the restarting management server.  The
    logic has been updated so that the data is properly cleared and
    handled.
    
    The fix for this APAR is included in the following maintenance
    vehicle:
        | fix pack | 6.2.1-TIV-ITM-FP0003
    

Temporary fix

Comments

APAR Information

  • APAR number

    IZ76004

  • Reported component name

    TEMS

  • Reported component ID

    5724C04MS

  • Reported release

    621

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-05-13

  • Closed date

    2010-06-25

  • Last modified date

    2010-07-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    OA33556

Fix information

  • Fixed component name

    TEMS

  • Fixed component ID

    5724C04MS

Applicable component levels

  • R621 PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"621"}]