IBM Support

IZ75211: ITM INSTALLER TAKES TOO LONG WITH LARGE ITMHOME

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PROBLEM DESCRIPTION:
    In specific configuration where the $CANDLEHOME filesystem is
    massive, the "tacmd exportbundles" command may take a time time
    to execute. Find commands in install.sh
    and cic.jar will take too long, up to two hours or more to
    deploy or install an OS Agent.
    
    RECREATE INSTRUCTIONS:
    Install some ITM agents and components.
    Create 30 - 100 copies of Candlehome saved as hidden directories
    within $CANDLEHOME.
    Upgrade agents to ITM 6.22 FP2
    
    
    == L3 Approver: AS
    

Local fix

  • Reduce the size of $CANDLEHOME, for instance by temporarily
    moving out hidden backup directories.
    

Problem summary

  • When CANDLEHOME contains a larger than normal number of files,
    the install process takes a very long time.  The problem case
    was caused by customer-generated backup files kept in hidden
    directories within CANDLEHOME.
    

Problem conclusion

  • The code was changed to avoid searching hidden directories under
    the CANDLEHOME directory.
    
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
      | fix pack | 6.2.2-TIV-ITM-FP0003
    

Temporary fix

Comments

APAR Information

  • APAR number

    IZ75211

  • Reported component name

    OMEG DIST INSTA

  • Reported component ID

    5608A41CI

  • Reported release

    622

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-04-28

  • Closed date

    2010-09-27

  • Last modified date

    2010-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    OMEG DIST INSTA

  • Fixed component ID

    5608A41CI

Applicable component levels

  • R622 PSY

       UP