Error description
Not returning what processNodeListUpdates returns. Tolerating a failed Node List resync should be relatively simple.
Local fix
No workaround available
Problem summary
Synchronization of the nodelist from the HUB to the remote management server can fail when a brief communication issue occurs during the synchronization. The failure is not handled properly resulting in an inaccurate nodelist at the remote Tivoli Enterprise Management Server. The inaccurate nodelist can result in incorrect or missing situation distributions at the remote Tivoli Enterprise Management Server.
Problem conclusion
The code has been updated to recognize that the nodelist synchronization failed. Additional trace error messages have been added that will document when a failure in the nodelist synchronization occurs. The fix for this APAR is included in the following maintenance vehicle: | fix pack | 6.2.1-TIV-ITM-FP0003
Temporary fix
Restart the remote Tivoli Enterprise Management Server to correct nodelist and situation distributions.
Comments
APAR Information
APAR number
IZ71695
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
621
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-02
Closed date
2010-05-26
Last modified date
2010-07-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R621 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"621"}]
Document Information
Modified date:
30 December 2022