Readmes are available
IBM Tivoli 4.0.0-TIV-SSM-FP0010
IBM Tivoli 4.0.0-TIV-SSM-FP0011
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 12 README 4.0.0-TIV-SSM-FP0012
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 13 README 4.0.0-TIV-SSM-FP0013
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 14 README 4.0.0-TIV-SSM-FP0014
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.14-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.0.14-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.0.14-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.0.14-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 5 README 4.0.0.14-TIV-SSM-IF0005
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 6 README 4.0.0.14-TIV-SSM-IF0006
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 7 README 4.0.0.14-TIV-SSM-IF0007
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 8 README 4.0.0.14-TIV-SSM-IF0008
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.15-TIV-SSM-IF0001
APAR status
Closed as program error.
Error description
Some customers need to be able to view debug-level log information without restarting the SSM which impacts the current start of monitoring. There is presently no way to do this because the "LogLevel" variable in init.cfg is only read on startup/reboot. A new console command is required to change the log level dynamically at runtime.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All SSM 4.0 users. **************************************************************** PROBLEM DESCRIPTION: There is no way to change the SSM log level at run-time **************************************************************** RECOMMENDATION: Upgrade to Fix Pack 9 for SSM 4.0. ****************************************************************
Problem conclusion
Added a new core console command: "loglevel": Syntax: loglevel [1-5 | fatal | warning | information | verbose | debug] The command takes any valid value of the "LogLevel" inivar and returns the integer value of the log level that has been applied (in $?). The command also changes the inivar LogLevel and init.cfg immediately. This can be applied externally using the console: ssmcons -c "loglevel debug" The fix for this APAR is contained in the following maintenance packages: | fix pack | 4.0.0-TIV-SSM-FP0009
Temporary fix
Comments
APAR Information
APAR number
IZ71089
Reported component name
NETCOOL SYS SVC
Reported component ID
5724P4300
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-02-25
Closed date
2010-03-17
Last modified date
2010-03-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL SYS SVC
Fixed component ID
5724P4300
Applicable component levels
R400 PSN
UP
Document Information
Modified date:
17 March 2010