  • ********************** START OF APAR OPEN TEMPLATE
    *********************
    
    * Please open an apar with the following severity and
    information:     *
    *
    *
    APAR Type:            Field
    Approver Initials:    sm
    Severity:             3
    Reported Release:     621
    Compid:               5724C04EP TEP
    ABSTRACT:             default event dest cannot be restored
    
    
    PROBLEM DESCRIPTION:
    We have added some eventdestinations and modified the situation
    to send
    to the new destination instead of the default one. When we try
    to set
    the default destination on the left again and put the new
    eventdestination back to the rights side, this seems not to be
    kept.
    After closing/reopening the situation the new eventdestinations
    is the
    one selected again and the default isn't longer.
    
    RECREATE INSTRUCTIONS:
    1.
    Log in to the TEP and open the situation editor
    
    2.
    Browse to any situation
    
    3.
    Go to the EIF tab
    
    4.
    Make sure that the "Forward Events to an EIF Receiver" is
    checked
    
    Move the "<Default EIF Receiver>" to the Available box and move
    your
    newly created receiver (myTEC) to the assigned EIF receivers box
    
    Then apply the changes and close the situation.
    
    5.
    Now open the same situation and return to the EIF tab.
    
    You need to switch the Receivers back, so that the default is
    not the
    assigned and the myTEC receiver is in the list of available
    receivers.
    
    Apply again and close the situation.
    
    6.
    If you now reopen the same situation and check the EIF tab you
    can see
    that the switch back of the receivers has not been saved, so you
    are
    stuck with the newly created adapter and you cannot re assign
    the
    original default adapter on its own.
    
    LOCAL FIX: N/A
    
    *********************** END OF APAR OPEN TEMPLATE
    **********************
    

Local fix

  • N/A
    

Problem summary

  • In the Situation Editor, the default EIF receiver cannot be
    moved back to the Assigned EIF receivers column by itself after
    it has been moved to the available column and saved, and then
    moved back.  This only occurs when there is more than one EIF
    receiver created.  If you try to put the default EIF receiver in
    the assigned column by itself after it has been moved to the
    available column with at least one other EIF receiver, when the
    Situation editor is brought back up, the previous Assigned list
    will still be in effect.
    

Problem conclusion

  • The default EIF receiver may now be moved at will to and from
    the Assigned column and the Available column and saved, and it
    will be saved in the correct column.  An incorrect check was
    found that caused the original setting (before making the
    change) to be saved.
    
    The fix for this APAR is included in the following maintenance
    vehicle:
        | interim fix | 6.2.1-TIV-ITM-FP0003
    

Temporary fix

  • If you want only the Default EIF receiver to be assigned, then
    move all of the EIF receivers to the Available column and click
    OK.  When the Situation Editor is brought back up, the Default
    EIF receiver will be the only entry on the assigned EIF
    receivers side.
    

Comments

APAR Information

  • APAR number

    IZ68376

  • Reported component name

    TEP

  • Reported component ID

    5724C04EP

  • Reported release

    621

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-20

  • Closed date

    2010-04-27

  • Last modified date

    2010-07-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TEP

  • Fixed component ID

    5724C04EP

Applicable component levels

  • R621 PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"621"}]

Document Information

Modified date:
30 December 2022