Readmes are available
IBM Tivoli 4.0.0-TIV-SSM-FP0010
IBM Tivoli 4.0.0-TIV-SSM-FP0011
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 12 README 4.0.0-TIV-SSM-FP0012
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 13 README 4.0.0-TIV-SSM-FP0013
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 14 README 4.0.0-TIV-SSM-FP0014
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.14-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.0.14-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.0.14-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.0.14-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 5 README 4.0.0.14-TIV-SSM-IF0005
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 6 README 4.0.0.14-TIV-SSM-IF0006
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 7 README 4.0.0.14-TIV-SSM-IF0007
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 8 README 4.0.0.14-TIV-SSM-IF0008
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.15-TIV-SSM-IF0001
APAR status
Closed as program error.
Error description
SSM 4.0 FP 8 Windows 2003 32bits : error using srLogMon . Description: Customer has two hosts equipped with Windows 2003 Server SP2 (1 with 32 bits, with 64 bits edition). They have installed SSM 4.0 with FixPack 8. No error occurs when installing the agent. No error too when the agent starts. After a while, the console displays the error : srLogMon: An internal Windows error occured extracting message ID 552 from C:\WINDOWS\System32\MsAuditE.dll srLogMon: An internal Windows error occured extracting message ID 552 from C:\WINDOWS\System32\MsAuditE.dll
Local fix
N/A
Problem summary
**************************************************************** USERS AFFECTED: Users of srLogMon/LogMonX on Windows **************************************************************** PROBLEM DESCRIPTION: A spurious log message appears in ssmagent.log: srLogMon: An internal Windows error occured extracting message ID **************************************************************** RECOMMENDATION: Upgrade to Fix Pack 9 for SSM 4.0. ****************************************************************
Problem conclusion
The log message itself was wrong. Windows event log monitoring is operating correctly. The log message has been removed. The fix for this APAR is contained in the following maintenance packages: | fix pack | 4.0.0-TIV-SSM-FP0009
Temporary fix
Comments
APAR Information
APAR number
IZ67701
Reported component name
NETCOOL SYS SVC
Reported component ID
5724P4300
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-01-08
Closed date
2010-01-15
Last modified date
2010-01-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL SYS SVC
Fixed component ID
5724P4300
Applicable component levels
R400 PSN
UP
Document Information
Modified date:
15 January 2010