IBM Support

IZ59540: SITUATION PERSISTENCE IN TEP BEING RESET TO 99.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment : ITM 6.21 IF3
    Platform    : All components - Windows
    Problem Desc: Situation Persistence "Consecutive true samples"
    is
                  limited to 99.  'tacmd viewsit' is not limited
    Reproduction:
    
    Open Situation Editor
    Edit any Situation
    On 'Formula' tab, click on 'Advanced' button
    Enter "150" for "Consecutive true samples"
    Click OK
    Click on 'Advanced' button again.
    Confirm '150' still set
    Click OK, and OK again to exit Situation Editor
    
    Re-edit the situation
    On 'Formula' tab, click on 'Advanced' button
    Observe that "Consecutive true samples" is now '99'
    
    Examine situation export through 'tacmd viewsit -s -e' and
    observe
    that 'SITINFO' contains the correct value (in this example, 150)
    
    - <SITINFO>
        <![CDATA[ COUNT=150;TFWD=Y;TDST=0;~;  ]]>
      </SITINFO>
    

Local fix

  • non
    

Problem summary

  • In the advanced dialog on the situation editor, if the user sets
    a persistence count greater than 99, then closes the situation
    editor, upon reopening the editor the persistence count is reset
    to 99.
    

Problem conclusion

  • Changed persistence count limit to 999.
    
    The persistence count was stored correctly in the management
    server, only the GUI display was incorrect.
    
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
       | fix pack | 6.2.1-TIV-ITM-FP0001
    

Temporary fix

Comments

APAR Information

  • APAR number

    IZ59540

  • Reported component name

    TEMA

  • Reported component ID

    5724C04TE

  • Reported release

    621

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-28

  • Closed date

    2009-10-15

  • Last modified date

    2009-12-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TEP

  • Fixed component ID

    5724C04EP

Applicable component levels

  • R621 PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"621"}]

Document Information

Modified date: