  • Abstract: 64 bit UI package not installed properly on AIX
    machines
    
    Environment: UI and CI components, AIX platform, 32 & 64 bit
    
    Problem Description:
    
    Customer was not able to use the "tacmd" command on a system
    where the
    TEPS, the WHP and the S&P agent were installed.
    
    Both bit-versions of UI files are needed on the AIX platforms
    for
    certain operations to execute properly, and the 64-bit UI were
    missing,
    causing the execution problem.
    
    Detailed Recreation Procedure:
    
    1. Clean install of ITM 6.2 FP1. You must install on an AIX 5.3
    64 bit
    or AIX 6.1 platform to be able to recreate the problem.
    2, If you install any, or all, of kcq, khd, ksy, you will see
    the
    problem.  If you install kux, you will never see the problem
    because ku
    prereqs kui 64.  If you install kms (TEMS), you will never see
    the
    problem because kms prereqs both kui 32 and kui 64.
    2. Run tacmd login or some other command, you will see the
    failure:
    
    # bin/cinfo -i
    
    *********** Tue Mar  3 17:05:03 CST 2009 ******************
    User: root Groups: system bin sys security cron audit lp
    Host name : 538d2lp2.tivlab.austin.ibm.com       Installer
    Lvl:06.20.01.00
    CandleHome: /data/css/CH
    ***********************************************************
    ...Product inventory
    
    ax      IBM Tivoli Monitoring Shared Libraries
             aix523  Version: 06.20.01.00
    
    hd      Warehouse Proxy
             aix523  Version: 06.20.01.00
    
    jr      Tivoli Enterprise-supplied JRE
             aix523  Version: 05.05.00.00
             aix526  Version: 05.05.00.00
    
    ui      Tivoli Enterprise Services User Interface
             aix523  Version: 06.20.01.00
    
    # bin/tacmd
    tacmd failure: product "ui" not installed for this architecture.
    
    
    Related Files and Output: NA
    
    Approver: CS
    

Local fix

Problem summary

  • Installing the Tivoli Enterprise Portal Server, Warehouse Proxy
    Agent, or Summarization & Pruning agent on an AIX 64 bit system
    does not install a usable tacmd command for this system.
    
    The tacmd package for AIX 32 bit only is installed by the Tivoli
    Enterprise Portal Server, Warehouse Proxy Agent, or
    Summarization & Pruning agent whether it is installed onto an
    AIX 32 bit or 64 bit system.  The tacmd package for 32 bit will
    not run on AIX 64 bit.
    

Problem conclusion

  • The code was modified so that when installing on a AIX 64 bit
    system and the tacmd package for AIX 32 bit is being installed,
    the tacmd package for 64 bit is installed as well.
    
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
       | fix pack | 6.2.0-TIV-ITM-FP0003
    

Temporary fix

  • Manually install the tacmd package for AIX 64 bit.  This is the
    Tivoli Enterprise Services User Interface item.
    

Comments

APAR Information

  • APAR number

    IZ45139

  • Reported component name

    OMEG DIST INSTA

  • Reported component ID

    5608A41CI

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-03-04

  • Closed date

    2009-04-22

  • Last modified date

    2009-04-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    OMEG DIST INSTA

  • Fixed component ID

    5608A41CI

Applicable component levels

  • R620 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
14 November 2022