IBM Support

IZ14553: INCORRECT VALUE DISPLAYED IN THE NAVIGATOR FOR A SITUATION USING A UTF-8 COLUMN.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem Description:
    A situation using a UTF-8 column as the display item (atomize
    value) indicates an incorrect value in the navigator view when
    an event is raised.  This is due to a buffer overflow at the
    time that the atomize column is found.
    Parsing of the returned values is retried stripping out
    trailing blanks but flags are not reset and so the first
    column value processed is used as the atomize value.
    
    Detailed Recreation Procedure:
    Have not recreated inhouse.  Easily recreatable by the
    customer.
    Related Files and Output:
    Logs are available on ECuRep.
    
    Environment:
     AIX TEMS KFA This is not a regression.
    

Local fix

Problem summary

  • A situation using a UTF-8 column as the display item (atomize
    value) indicates an incorrect value in the navigator view when
    an event is raised.  This is due to a buffer overflow after the
    atomize column is found.  Parsing of the returned values is
    retried stripping out trailing blanks but flags are not reset
    and so the first column value processed is used as the atomize
    value.
    

Problem conclusion

  • The code was modified to reset the AtomizeFound flag when a
    buffer overflow is detected.
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
       | interim fix | 6.1.0.7-TIV-ITM-IF0003
    

Temporary fix

Comments

APAR Information

  • APAR number

    IZ14553

  • Reported component name

    TEMS

  • Reported component ID

    5724C04MS

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-02-01

  • Closed date

    2008-12-15

  • Last modified date

    2008-12-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    OA27233 OA28015

Fix information

  • Fixed component name

    TEMS

  • Fixed component ID

    5724C04MS

Applicable component levels

  • R610 PSY

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCTLMP","label":"ITM Tivoli Enterprise Mgmt Server V6"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
15 December 2008