  • STEPS TO REPRODUCE:
    - Go to System Properties application.
    - Find the webclient.useClientTimer property.
    - Its value is already set to = 1
    - Go to Work Order Tracking application
    - Find an existing WO record (e.g. in Wappr status)
    - Open the Calendar lookup for any DateTime field, such as
    Scheduled Start
    - The TimePicker on the right shows a number of timeslots.
    - The range of the timeslots is 12.00am (midnight) - 2.45am
    - This is always the case regardless of the client machine's
    local time
    - It should show a range of timeslots showing a 2-hour range
    matching the current DateTime on the client machine
    - The webclient.useClientTimer property's value of 1 is
    therefore not taken into account
    CURRENT ERRONEOUS RESULT:
    The webclient.useClientTimer property's value of 1 is therefore
    not taken into account
    EXPECTED RESULT:
    If webclient.useClientTimer = 1, then the Time picker should
    adjust to display timeslots matching the current System
    DateTime (including one hour before SYSDATE and one hour after
    SYSDATE)
    ADDITIONAL INFO:
    This was working in Maximo 7.5.0.x up to Maximo 7.5.0.7
    New system property 'webclient.useClientTimer' was then added
    to adjust the default time on the Date/Time Calendar widget to
    use the client workstation's local time.
    

Local fix

  • Users need to scroll down to the relevant timeslot close to
    current SysDateTime.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Maximo Users                                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Time picker on calendar lookup defaults to 12.00am.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to latest release                                    *
    ****************************************************************
    STEPS TO REPRODUCE:
    - Go to Work Order Tracking application
    - Find an existing WO record (e.g. in Wappr status)
    - Open the Calendar lookup for any DateTime field, such as
    Scheduled Start
    - The TimePicker on the right shows a number of timeslots.
    - The range of the timeslots is 12.00am (midnight) - 2.45am
    - This is always the case regardless of the client machine's
    local time
    - It should show a range of timeslots showing a 2-hour range
    matching the current DateTime on the client machine
    
    CURRENT ERRONEOUS RESULT:
    Time picker on calendar lookup does not display the correct
    range of times.
    
    EXPECTED RESULT:
    Time picker should adjust to display timeslots matching the
    current System DateTime.
    

Problem conclusion

  • Time picker on calendar lookup shows a range of times that
    includes the selected time or current time.
    
    The fix for this APAR is contained in the following maintenance
    package:
    	 | release\fix pack | Fix Pack Release 7.6.0.8 TPAE
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV90424

  • Reported component name

    SYSTEM CONFIG

  • Reported component ID

    5724R46S1

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-11-01

  • Closed date

    2017-02-23

  • Last modified date

    2017-02-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    SYSTEM CONFIG

  • Fixed component ID

    5724R46S1

Applicable component levels

  • R760 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
23 February 2017