A fix is available
APAR status
Closed as program error.
Error description
APAR Type: Field Approver Initials: mww Severity: 3 Reported Release: 622 Compid: 5724C04VP VIOS Premium Agent ENVIRONMENT: IBM Tivoli Monitoring for System p - VIOS Premium Agent 6.2.2.2 PROBLEM DESCRIPTION: The errpt will report a LINK ERROR on a Fibre Channel adapter that does not have SCSI devices. This might occur when collecting data for Fibre Channel attributes. RECREATE INSTRUCTIONS: 1) Install a Fibre Channel adapter with LAN but no SCSI devices. 2) From the Tivoli Enterprise Portal, go to the Storage--Fibre Channel workspace. 3) Run "errpt -a" and look for "LABEL: FCA_ERR4" and Description "LINK ERROR" with Resource of a Fibre Channel adapter.
Local fix
Problem summary
********************************************************* * USERS AFFECTED: All users. ********************************************************* * PROBLEM DESCRIPTION: * The errpt reports a LINK ERROR on a Fibre Channel * adapter that does not have SCSI devices. ********************************************************* * RECOMMENDATION: Apply 6.2.2.2-TIV-ITM_VIOS_PREM-IF0006. ********************************************************* Interim Fix 6.2.2.2-TIV-ITM_VIOS_PREM-IF0006 resolves the problem by removing the API call that caused the error.
Problem conclusion
The fix for this APAR will be contained in the following maintenance packages: | interim fix | 6.2.2.2-TIV-ITM_VIOS_PREM-IF0006
Temporary fix
Comments
APAR Information
APAR number
IV62823
Reported component name
ITM SE SYSP VIO
Reported component ID
5724C04VP
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-22
Closed date
2014-10-29
Last modified date
2014-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITM SE SYSP VIO
Fixed component ID
5724C04VP
Applicable component levels
R622 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622","Edition":"","Line of Business":{"code":"","label":""}}]