Direct links to fixes
4.1.1-TIV-SAMP-Linux64-FP0001
4.1.1-TIV-SAMP-AIX-FP0001
4.1.0-TIV-SAMP-AIX-FP0001
4.1.0-TIV-SAMP-Linux-FP0001
4.1.0-TIV-SAMP-Linux64-FP0001
4.1.0-TIV-SAMP-AIX-FP0002
4.1.0-TIV-SAMP-Linux64-FP0002
4.1.0-TIV-SAMP-Linux-FP0002
3.2.2-TIV-SAMP-Linux-FP0009
3.2.2-TIV-SAMP-AIX-FP0009
3.2.2-TIV-SAMP-Solaris-FP0009
3.2.2-TIV-SAMP-Windows-FP0009
3.2.2-TIV-SAMP-Windows-FP0009
4.1.0-TIV-SAMP-AIX-FP0003
4.1.0-TIV-SAMP-Linux-FP0003
4.1.0-TIV-SAMP-Linux64-FP0003
4.1.0-TIV-SAMP-AIX-FP0006
4.1.0-TIV-SAMP-Linux-FP0006
4.1.0-TIV-SAMP-Linux64-FP0006
4.1.0-TIV-SAMP-AIX-FP0007
4.1.0-TIV-SAMP-Linux64-FP0007
SAMP4107_Verification_Signatures
4.1.1-TIV-SAMP-AIX-FP0000
4.1.1-TIV-SAMP-Linux64-FP0000
3.2.2-TIV-ITSAMP-FP0009, Tivoli System Automation for Multiplatforms
4.1.0-TIV-ITSAMP-FP0003, Tivoli System Automation for Multiplatforms
4.1.0-TIV-ITSAMP-FP0004, Tivoli System Automation for Multiplatforms
APAR status
Closed as program error.
Error description
Support Engineer: GBH Change Team Eng: MM Environment: TSAMP v4.1 Details: Given two comprising groups with nested groups inside: her-rg ( running per default on node01 ) her-app-rg ( holds 15 app resources ) her-fs-rg ( holds file systems ) luc-rg ( holds 4 app resources, running per default on node node02) luc-fs-rg ( holds file systems ) Both RGs are per default running on different nodes. We have some startafter relations between apps from luc-rg to apps in nested group her-app-rg, which all work well, also during a move of the comprising group her-rg. Then we created a forcedownby rel from IBM.Application:sehefeeder ( luc-rg ) to IBM.Application:hermid ( her-app-rg ) Now, when moving the comprising group her-rg, not only IBM.Application:hermid goes down ( which would be correct ). As soon as now the nested group her-fs-rg goes down, also the nested group luc-fs-rg goes down. And that of course causes the whole stuff in luc-rg to be restarted. And as a side effect, if both RGs are on the same node and her-rg is moved back, the luc-rg follows her-rg to the other node. As soon as we removed the forcedownby-rel, the luc-fs-rg stays online during the move... Then we used dependsonany instead of forcedownby. The results are the same EXCEPT that luc-rg does'nt follow her-rg to the other node anymore.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * Tivoli System Automation for Multiplatforms (SA MP) 4.1 users **************************************************************** * PROBLEM DESCRIPTION: * The ForcedDownBy relationship is not working as expected in * complex environments where this relationship has been defined * between resources that are members of different nested * resource groups. If the target resource of the relationship * fails, the source resource is stopped as expected, but in * addition to that, other unrelated resources are stopped and * restarted too. * As a side effect the resources grouped together with the * source resource of the relationship might be moved unnecessary * to the same node as the target resource of the relationship in * case the resource group containing the target resource of the * ForcedDownBy relationship is moved. **************************************************************** * RECOMMENDATION: ****************************************************************
Problem conclusion
The internal handling of the ForcedDownBy relationship has been adjusted to address this issue. . The official fix for this issue is included in Tivoli System Automation for Multiplatforms 4.1 fix pack 1 | 4.1.0-TIV-ITSAMP-FP0001 | . Additional Search Keywords .
Temporary fix
Comments
APAR Information
APAR number
IV61171
Reported component name
SA MULTIPLATFOR
Reported component ID
5724M0000
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-06-03
Closed date
2014-07-28
Last modified date
2014-07-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SA MULTIPLATFOR
Fixed component ID
5724M0000
Applicable component levels
Document Information
Modified date:
25 September 2023