Error description
APAR Type: Field Approver Initials: mww Reported Release: 622 ENVIRONMENT: IBM Tivoli Monitoring for System p - HMC Base Agent 6.2.2.3 PROBLEM DESCRIPTION: If the HMC time zone is set to time zone BST, which can be more than one time zone, for example, British Summer Time and Bangladesh Standard Time, CPU data might not be collected because the data provider might use the incorrect time zone. When the data provider sends the commands to the HMC to collect the CPU data, the start and stop times of the commands might not be correct and might not receive any data. It is also possible that data will be collected, but for the wrong time frame. RECREATE INSTRUCTIONS: On the HMC, set the time zone to BST and set the time to the current time in England.
Local fix
Set the time zone on the HMC to the GMT time zone.
Problem summary
*************************************************************** * USERS AFFECTED: HMC systems with BST or CST time zones. *************************************************************** * PROBLEM DESCRIPTION: The agent will not display CPU data. *************************************************************** * RECOMMENDATION: Apply 6.2.2.3-TIV-ITM_HMC_BASE-IF0003. *************************************************************** Interim Fix 6.2.2.3-TIV-ITM_HMC_BASE-IF0003 resolves the problem by using a different scheme for determining the time zone.
Problem conclusion
The fix for this APAR is contained in the following maintenance package: | interim fix | 6.2.2.3-TIV-ITM_HMC_BASE-IF0003
Temporary fix
Comments
APAR Information
APAR number
IV60709
Reported component name
ITM SE SYSP HMC
Reported component ID
5724C04HB
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-20
Closed date
2014-09-24
Last modified date
2014-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITM SE SYSP HMC
Fixed component ID
5724C04HB
Applicable component levels
R623 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
26 August 2022