IBM Support

IV57575: IN 7.2.2.1 CUSTOM EXTENSIONS WITH SCRIPT DIRECTIVES FAIL TO RUN.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • In 7.2.2.1, running a script directive returns the error "no
    module named java" in the sensor log and the script is not run.
    The sensor still ends successfully, although the custom data is
    not captured.
    
    At this point in time this is believed to be a Unix issue
    related to the permissions on directory dist/bin/cachedir.
    

Local fix

  • Delete directory dist/bin/cachedir after applying 7221 on Unix
    TADDM Discovery Servers and re-run discovery.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * NONE                                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In 7.2.2.1, running a script directive returns the error "no *
    * module named java" in the sensor log and the script is not   *
    * run.                                                         *
    * The sensor still ends successfully, although the custom data *
    * is                                                           *
    * not captured.                                                *
    *                                                              *
    * At this point in time this is believed to be a Unix issue    *
    * related to the permissions on directory dist/bin/cachedir.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * NONE                                                         *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    packages:
    | Fix Pack | 7.2.2-TIV-ITADDM-FP0002
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV57575

  • Reported component name

    APP DEPENDENCY

  • Reported component ID

    5724N5500

  • Reported release

    722

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-03-27

  • Closed date

    2014-06-24

  • Last modified date

    2014-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP DEPENDENCY

  • Fixed component ID

    5724N5500

Applicable component levels

  • R722 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSPLFC","label":"Tivoli Application Dependency Discovery Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"722","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
24 June 2014