APAR status
Closed as program error.
Error description
APAR Type: Field Approver Initials: RB Severity: 3 Reported Release: 630 Compid: 5724C04MS Tivoli Enterprise Management Server ABSTRACT: Agents time out when heartbeat backlog exists PROBLEM DESCRIPTION: Online agents can be incorrectly timed out if a backlog of heartbeats occurs. This problem can occur when a large number of agents are attempting to register at an RTEMS and the connection between the RTEMS and the HUB is slow. The backlog that develops can prevent heartbeats from currently connected agents from being processed in a timely manner. RECREATE INSTRUCTIONS: This is difficult to recreate and require a slow connection between the RTEMS and HUB. Improve the time it takes to send data between the RTEMS and the HUB or reduce the number of agents connected to the RTEMS.
Local fix
Improve the time it takes to send data between the RTEMS and the HUB or reduce the number of agents connected to the RTEMS.
Problem summary
Monitoring agents may time out when a heartbeat backlog exists. In systems with very large numbers of agents heartbeating, some agents can be set off-line because the second heartbeat from any given agent may not be processed until after the heartbeat grace period has expired.
Problem conclusion
The code has been changed to always give priority to processing node heartbeats over node timeouts. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0004
Temporary fix
Comments
APAR Information
APAR number
IV56652
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-13
Closed date
2014-11-18
Last modified date
2014-12-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R630 PSY
UP