IV48351: SITUATION BASED ON CPU USED PCT TRIGGERS ERRONEOUSLY AT STARTUP.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A situation based on the attribute CPU Used Pct in the
    Processor attribute group triggers erroneously at start-up.
    
    Approver:         MK
    

Local fix

Problem summary

  • Situation based on "% CPU Used" attribute triggers erroneously
    at startup.
    
    
    A situation based on the "% CPU Used" attribute in the "KR6 SMA
    Processor" attribute group triggers erroneously at startup.
    

Problem conclusion

  • The "% CPU Used" attribute value is based on the calculation of
    several attributes which are defined as SNMP Counter values.
    These values can grow over time, so the code calculates the
    delta from the current value with the previous one.  At agent
    startup, if the situation runs before the second data
    collection, the attribute value would be set to 100 and the
    situation would trigger. Code has been updated to handle this
    condition correctly.
    
    This only affects the Monitoring Agent for Agentless Solaris OS
    when configured with the Connection Type of "SNMP (System
    Management Agent)".
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
      | fix pack | 6.3.0-TIV-ITM-FP0003
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV48351

  • Reported component name

    ITM REMOTE SOLA

  • Reported component ID

    5724C04RS

  • Reported release

    622

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-12

  • Closed date

    2013-12-16

  • Last modified date

    2014-08-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITM REMOTE SOLA

  • Fixed component ID

    5724C04RS

Applicable component levels

  • R630 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
30 December 2022