Readmes are available
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.14-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.0.14-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.1.1-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.1.1-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.0.14-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.1.1-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.0.14-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 2 README 4.0.1-TIV-SSM-FP0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.1.2-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 5 README 4.0.0.14-TIV-SSM-IF0005
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.1.2-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 6 README 4.0.0.14-TIV-SSM-IF0006
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.1.2-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 7 README 4.0.0.14-TIV-SSM-IF0007
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.1.2-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 8 README 4.0.0.14-TIV-SSM-IF0008
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.1.3-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.15-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.1.3-TIV-SSM-IF0002
APAR status
Closed as program error.
Error description
SSM 4.0 : The CD/DVDW TS-T632A DVD drive is incorrectly detected as a hard disk in the hrStorageTable.
Local fix
na
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of the SSM on Solaris Systems with a CD/DVDW TS-T632A * * Optical drive * **************************************************************** * PROBLEM DESCRIPTION: * * The drive is incorrectly marked as a Hard Disk in the * * htStorageTable * **************************************************************** * RECOMMENDATION: * * Upgrade to SSM 4.0.1.1 IF0001 * ****************************************************************
Problem conclusion
Drive is now detected as an optical drive. The fix for this APAR is contained in the following maintenance packages: | interim fix | 4.0.0.14-TIV-SSM-IF0001 | interim fix | 4.0.1.1-TIV-SSM-IF0001
Temporary fix
Comments
APAR Information
APAR number
IV43877
Reported component name
NETCOOL SYS SVC
Reported component ID
5724P4300
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-06-07
Closed date
2013-07-05
Last modified date
2014-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL SYS SVC
Fixed component ID
5724P4300
Applicable component levels
Document Information
Modified date:
05 March 2014