IBM Support

IV41655: VALUES SPECIFIED WITH CMA_CONFIG IN THE RESPONSE FILE NOT EFFECTIVE WHEN UPGRADING EXISTING AGENT.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment:
    Windows ONLY. Upgrade of 6.2.2 FP9 NT Agent to 6.2.3 FP1 NT
      Agent.
    
    Problem Description:
      When coding new connection parameters the number of protocols
      coded must match the existing number, or residual values will
      remain. Also the agent must be unconfigured before the
      upgrade. See examples that follow to see how the protocols
      work.
    
      Primary Protocols
      protocol1=IP.SPIPE
      protocol2=IP.PIPE
      FTO protocols
      FTO_protocol1=IP.SPIPE
      FTO-protocol2-IP.PIPE
    
      If only IP.SPIPE is coded in the CMA_CONFIG area of the silent
      install file, the IP-PIPE value is retained. However, if
      protocol2 is coded as protocol2=IP.SPIPE and
      FTO_protocol2=IP.SPIPE then only the IP.SPIPE value is
      retained.
    
    
    Recreate Instructions:
      1. Install 6.2.2 FP9 NT agent and configure as follows:
         Primary TEEMS Connection
         protocol1=IP.SPIPE
         protocol2=IP.PIPE
         Configure Secondary TEMS Connection:
         protocol1=IP.SPIPE
         protocol2=IP.PIPE
      2. Upgrade to 6.2.3 FPx where fix is present silently:
         a. Stop the agent
         b. Unconfigure the agent
         c. Add the following to the upgrade silent file
            [CMA_CONFIG]
            Protocol1=IP.SPIPE
            IPSPIPE_Port=3660
            IPSPIPE_Host=TEMSHOSTNAME
            FTO Flag=Y
            FTO_Protocol1=IP.SPIPE
            FTO_IPSPIPE_Host=FTOTEMSHOSTNAME
      3. If the fix is present only 1 protocol will remain for the
         NT agent.
         If the fix is not present, both IP.SPIPE and IP.PIPE
         protocols will be present.
      4. The problem is in the Agent Defaults area. If the defaults
         are going to be used they should reflect the settings in
         the silent install file.
    

Local fix

  • To work around this problem code the CMA section as follows:
    
        [CMA_CONFIG]
        Protocol1=IP.SPIPE
        Protocol2=IP.SPIPE
        IPSPIPE_Port=3660
        IPSPIPE_Host=PRIMARYTEMSHOSTNAME
        FTO Flag=Y
        FTO_Protocol1=IP.SPIPE
        FTO_Protocol2=IP.SPIPE
        FTO_IPSPIPE_Host=SECONDARYTEMSHOSTNAME
    
    By making protocol2 match protocol1 only that protocol will be
    retained.
    

Problem summary

  • On Windows, a user provides a [CMA_CONFIG] section in their
    silent install upgrade response file to change connection
    properties of the agents being upgraded. The information in the
    [CMA_CONFIG] section may be processed incorrectly during the
    upgrade. For example, if two protocols currently exist and only
    one is desired, the outcome of the configuration can be
    unpredictable.
    

Problem conclusion

  • Code was modified to process the response file during upgrade
    when an agent is reconfigured and the [CMA_CONFIG] section is
    present. The fix unconfigures any Primary agent or instances
    upgraded then configures them using the new protocol
    information.
    
    The fix for this APAR is contained in the following maintenance
    packages:
    | fix pack | 6.2.3-TIV-ITM-FP0005
    

Temporary fix

  • Reconfigure the agent and any instances using the Manage Tivoli
    Enterprise Monitoring Services tool after the upgrade completes,
     and configure them with the new protocol information.
    

Comments

APAR Information

  • APAR number

    IV41655

  • Reported component name

    OMEG DIST INSTA

  • Reported component ID

    5608A41CI

  • Reported release

    623

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-05-07

  • Closed date

    2013-10-31

  • Last modified date

    2014-05-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    OMEG DIST INSTA

  • Fixed component ID

    5608A41CI

Applicable component levels

  • R623 PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"623"}]

Document Information

Modified date:
30 December 2022